Cardiac output during labour.
- 7 November 1987
- Vol. 295 (6607) , 1169-1172
- https://doi.org/10.1136/bmj.295.6607.1169
Abstract
Serial measurements of cardiac output and mean arterial pressure were performed in 15 women during the first stage of labour and at one and 24 hours after delivery. Cardiac output was measured by Doppler and cross sectional echocardiography at the pulmonary valve. Basal cardiac output (between uterine contractions) increased from a prelabour mean of 6.99 l/min to 7.88 l/min at greater than or equal to 8 cm of cervical dilatation as a result of an increase in stroke volume. Over the same period basal mean arterial pressure also increased. During uterine contractions there was a further increase in cardiac output as a result of increases in both stroke volume and heart rate. The increment in cardiac output during contractions became progressively greater as labour advanced. At greater than or equal to 8 cm of dilatation cardiac output increased from a basal mean of 7.88 l/min to 10.57 l/min during contractions. There were also further increases in mean blood pressure during contractions. One hour after delivery heart rate and cardiac output had returned to prelabour values, though mean arterial pressure and stroke volume remained raised. By 24 hours after delivery all haemodynamic variables had returned to prelabour values. Haemodynamic changes of the magnitude found in this series are of considerable clinical relevance in managing mothers with complicated cardiovascular function.Keywords
This publication has 14 references indexed in Scilit:
- Haemodynamic changes during the early puerperium.BMJ, 1987
- Variable effects of changes in flow rate through the aortic, pulmonary and mitral valves on valve area and flow velocity: Impact on quantitative doppler flow calculationsJournal of the American College of Cardiology, 1985
- Efforts to combine endocrine and chemotherapy in the management of breast cancer: Do two and two equal three?Breast Cancer Research and Treatment, 1983
- [The observation of the maternal hemodynamics during labor and cesarean section (author's transl)].1982
- A phase II trial of tamoxifen, premarin, methotrexate and 5-fluorouracil in metastatic breast cancerBreast Cancer Research and Treatment, 1982
- Management of heart disease in pregnancyProgress in Cardiovascular Diseases, 1974
- The circulatory effects of recumbent postural change in late pregnancy.1967
- THE MECHANICAL EFFECTS OF THE GRAVID UTERUS IN LATE PREGNANCY*BJOG: An International Journal of Obstetrics and Gynaecology, 1965
- THE BLOOD PRESSURE IN NORMAL LABOURBJOG: An International Journal of Obstetrics and Gynaecology, 1958
- Cardiac output during laborAmerican Journal of Obstetrics and Gynecology, 1956