Membrane vs Bubble Oxygenator
- 1 May 1975
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Annals of Surgery
- Vol. 181 (5) , 747-753
- https://doi.org/10.1097/00000658-197505000-00033
Abstract
Numerous studies have demonstrated the superiority of membrane oxygenators (MO) over the bubble oxygenators (BO) when used for prolonged cardiopulmonary support. However, there is little information available evaluating the MO for routine, short-term cardiopulmonary bypass. In this study the 5MO314 Modulung-Teflo (MO) was compared to 5M30314 Miniprime Variflo (BO). The data of 91 patients (46 MO and 45 BO) were analyzed according to the duration of cardiopulmonary bypass (Group I less than 60 min., Group II 60-90 min. and Group III greater than 90 min.). Hemodynamic parameters, fluid and blood balance, as well as hematologic and blood gas studies were used for comparing the two oxygentors. The hemodynamic parameters were better, and the arterial blood gases were more physilogic with the MO. The postoperative blood loss was significantly less when using the MO. The other measurements documented the stability of the MO. All statements were based on statistical analysis with a DEC PDP-9 computer, using the MIIS language and operating system. Consequently, we are now using this MO for routine cardiopulmonary bypass.Keywords
This publication has 11 references indexed in Scilit:
- Is the Blood-Gas Interface of Clinical Importance?The Annals of Thoracic Surgery, 1974
- Blood-Gas Interface Oxygenators Versus Membrane Oxygenators: What Are the Proved Differences?The Annals of Thoracic Surgery, 1974
- Particulate Microembolism During Cardiac OperationThe Annals of Thoracic Surgery, 1974
- The Landé-Edwards membrane oxygenator for total cardiopulmonary support in 110 patients during heart surgery.1972
- Prolonged cardiopulmonary support with disposable membrane oxygenator during aortocoronary artery bypass grafts.1972
- A comparison of the microparticles produced when two disposable-bag oxygenators and a disc oxygenator are used for cardiopulmonary bypassThe Journal of Thoracic and Cardiovascular Surgery, 1972
- Minimal apparent blood damage in Landé-Edwards membrane oxygenator at physiologic gas tensionsThe Journal of Thoracic and Cardiovascular Surgery, 1970
- The Production of Microemboli by Various Blood OxygenatorsThe Annals of Thoracic Surgery, 1970
- Blood trauma produced by pump oxygenators: a comparative study of five different units.1969
- Biologic Evaluation of Blood After Prolonged Recirculation Through Film and Membrane OxygenatorsAnnals of Surgery, 1965