Quantitative Scanning Electron Microscopic Autoradiography of Inhaled 239PuO2

Abstract
We have applied the scanning electron microscope (SEM) to obtain autoradiographs of particles of 239PuO2 deposited in rat lung. The technique was used to obtain quantitative information on the clearance rates of particles from the alveoli, bronchioles and trachea up to 240 d after exposure. At all times, the concentration of particles on the surface of the bronchioles was an order of magnitude greater than on the treacheal surface. The clearance of Pu from both regions followed a biphasic pattern, similar to that obtained by radiometric analysis of the whole lung. Most of the radiation dose to the bronchiolar epithelium originated from Pu particles in peribronchiolar alveoli in which they were preferentially retained, compared to other alveolar regions. The prolonged retention of particles in the peribronchiolar alveoli may be a significant factor in the induction of lung carcinomas.