Impact of dose-distribution uncertainties on rectal ntcp modeling I: Uncertainty estimates
- 9 April 2001
- journal article
- Published by Wiley in Medical Physics
- Vol. 28 (4) , 560-569
- https://doi.org/10.1118/1.1333746
Abstract
A trial of nonescalated conformal versus conventional radiotherapy treatment of prostate cancer has been carried out at the Royal Marsden NHS Trust (RMH) and Institute of Cancer Research (ICR), demonstrating a significant reduction in the rate of rectal bleeding reported for patients treated using the conformal technique. The relationship between planned rectal dose-distributions and incidences of bleeding has been analyzed, showing that the rate of bleeding falls significantly as the extent of the rectal wall receiving a planned dose-level of more than 57 Gy is reduced. Dose-distributions delivered to the rectal wall over the course of radiotherapy treatment inevitably differ from planned distributions, due to sources of uncertainty such as patient setup error, rectal wall movement and variation in the absolute rectal wall surface area. In this paper estimates of the differences between planned and treated rectal dose-distribution parameters are obtained for the RMH/ICR nonescalated conformal technique, working from a distribution of setup errors observed during the RMH/ICR trial, movement data supplied by Lebesque and colleagues derived from repeat CT scans, and estimates of rectal circumference variations extracted from the literature. Setup errors and wall movement are found to cause only limited systematic differences between mean treated and planned rectal dose-distribution parameter values, but introduce considerable uncertainties into the treated values of some dose-distribution parameters: setup errors lead to 22% and 9% relative uncertainties in the highly dosed fraction of the rectal wall and the wall average dose, respectively, with wall movement leading to 21% and 9% relative uncertainties. Estimates obtained from the literature of the uncertainty in the absolute surface area of the distensible rectal wall are of the order of 13%-18%. In a subsequent paper the impact of these uncertainties on analyses of the relationship between incidences of bleeding and planned rectal dose-distributions is exploredKeywords
This publication has 15 references indexed in Scilit:
- Analysis of the dose‐surface histogram and dose‐wall histogram for the rectum and bladderMedical Physics, 1997
- Acute toxicity in pelvic radiotherapy; a randomised trial of conformal versus conventional treatmentRadiotherapy and Oncology, 1997
- Accuracy of pelvic radiotherapy: prospective analysis of 90 patients in a randomised trial of blocked versus standard radiotherapyRadiotherapy and Oncology, 1996
- Variation in volumes, dose-volume histograms, and estimated normal tissue complication probabilities of rectum and bladder during conformal radiotherapy of T3 prostate cancerInternational Journal of Radiation Oncology*Biology*Physics, 1995
- The Royal Marsden Hospital pelvic radiotherapy trial: technical aspects and quality assuranceRadiotherapy and Oncology, 1993
- Conformal radiotherapy of the pelvis: assessment of acute toxicityRadiotherapy and Oncology, 1993
- Decomposition of pencil beam kernels for fast dose calculations in three‐dimensional treatment planningMedical Physics, 1993
- Time trend of patient setup deviations during pelvic irradiation using electronic portal imagingRadiotherapy and Oncology, 1993
- The simultaneous boost technique: the concept of relative normalized total doseRadiotherapy and Oncology, 1991
- Mechanical properties of the colon: comparison of the features of the African and European colon in vitro.Gut, 1985