Interferences in the determination of lithium by flame atomic emission spectrometry with platinum-loop atomizer
- 1 January 1994
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 9 (7) , 797-800
- https://doi.org/10.1039/ja9940900797
Abstract
Although flame atomic emission spectrometry (AES) is the most popular method for the determination of Li, the method is subject to interference from alkaline and alkaline earth elements. The effects of CaOH and SrO emission bands are particularly severe. The use of a Pt-loop atomizer was found to eliminate interference from Ca and Sr, as salts of these elements remained as solid residues on the loop material. High contents of F–, Cl–, SO4 2– and PO4 3– were found to reduce the Li signal, this was largely due to loss of LiCl in the case of Cl–, in the case of F–, SO4 2– and PO4 3–, the reduction in the Li signal was due to lithium oxide formation. The accuracy of the Pt-loop technique was shown to be satisfactory in matrices of high Ca and Sr contents. The detection limit obtained with the Pt-loop was at least one order of magnitude better than that of conventional AES. The technique was applied in the determination of Li in several sample types.Keywords
This publication has 11 references indexed in Scilit:
- Determination of lithium at ultratrace levels in biological fluids by flame atomic emission spectrometry. Use of first-derivative spectrometryThe Analyst, 1992
- Matrix modifiers in graphite furnace atomic absorption analysis of trace lithium in biological fluidsAnalytical Biochemistry, 1985
- Determination of lithium, rubidium and strontium in foodstuffsThe Analyst, 1985
- Some problems observed in the determination of lithium in waste waters by atomic-absorption spectrophotometryThe Analyst, 1984
- Basic investigations on background problems in the platinum-loop method in comparison to graphite-furnace and flame atomic-absorption spectrophotometryTalanta, 1981
- Eine mikromethode der flammen-atomabsorptions- und emissionsspektrometrie (platinschlaufen-methode)—IISpectrochimica Acta Part B: Atomic Spectroscopy, 1981
- Eine mikromethode der flammen-atomabsorptions- und emissions-spektrometrie (platinschlaufen-methode)—I. Die grundlagen der methode—anwendung auf die bestimmung von blei und cadmium in trinkwasserSpectrochimica Acta Part B: Atomic Spectroscopy, 1979
- An ultramicro method for analysis of lithium and other biologically important cationsBiochimica et Biophysica Acta (BBA) - General Subjects, 1978
- Matrix problems in the determination of lithium by flameless (HGA) atomic-absorption spectrometry, and their solutionTalanta, 1977
- The nitrous oxide-acetylene flame in emission analysis—IISpectrochimica Acta Part B: Atomic Spectroscopy, 1968