Delivery of Ultrasonic Nebulized Aerosols to a Lung Model during Mechanical Ventilation
- 1 October 1993
- journal article
- research article
- Published by American Thoracic Society in American Review of Respiratory Disease
- Vol. 148 (4_pt_1) , 872-877
- https://doi.org/10.1164/ajrccm/148.4_pt_1.872
Abstract
Ultrasonic nebulizers may be particularly suitable for the administration of therapeutic aerosols to patients undergoing mechanical ventilation, but the amount of aerosol that reaches the patients' respiratory tract during ultrasonic nebulization has not been adequately studied. The delivery through an endotracheal tube of nebulized aerosols labeled with 99mTechnetium human serum albumin was therefore measured for five commercially available ultrasonic nebulizers using an in vitro model representing mechanical ventilation of an adult patient. Delivery of aerosol through the endotracheal tube ranged from 3.1 +/- 0.3% for Samsonic to 10.1 +/- 2.0% for Portasonic using 3 ml nebulizer solution. Increasing the volume of nebulizer solution to 18 ml (not possible for the Portasonic) increased delivery to 11.5 +/- 2.0 for the DP 100, 8.7 +/- 3.1 for Ultraneb, and 15.9 +/- 1.8% for Samsonic. Addition of a 600 ml aerosol storage chamber to the ventilator circuit increased delivery for the Samsonic (18 ml solution) to 22.3 +/- 5.0%. Aerosol delivery was also increased by reducing the respiratory rate and minute volume and by increasing the inspiratory time settings on the ventilator. These results confirm the potential value of ultrasonic nebulizers during mechanical ventilation and indicate that clinical trials in ventilated patients are warranted.Keywords
This publication has 11 references indexed in Scilit:
- Pulmonary deposition of a nebulised aerosol during mechanical ventilation.Thorax, 1993
- Delivery of a Nebulized Aerosol to a Lung Model during Mechanical Ventilation: Effect of Ventilator Settings and Nebulizer Type, Position, and Volume of FillAmerican Review of Respiratory Disease, 1992
- Nebulizer Function during Mechanical VentilationAmerican Review of Respiratory Disease, 1992
- Variability in the measurement of nebulized aerosol deposition in manClinical Science, 1991
- Droplets Produced by Medical NebulizersChest, 1990
- Pressurized Aerosol versus Jet Aerosol Delivery to Mechanically Ventilated Patients Comparison of Dose to the LungsAmerican Review of Respiratory Disease, 1990
- IMPROVING THE EFFICIENCY OF DRUG ADMINISTRATION WITH JET NEBULISERSThe Lancet, 1988
- Evaluation of Bronchodilator Responsiveness in Mechanically Ventilated PatientsAmerican Review of Respiratory Disease, 1987
- Particle Size Analysis of Nebulised Aerosols Using Fraunhofer Laser Diffraction and Inertial Compaction MethodsJournal of Pharmacy and Pharmacology, 1986
- Aerosol delivery in intubated, mechanically ventilated patientsCritical Care Medicine, 1985