Tomographic Reconstruction from Fan Beam Geometry Using Radon's Integration Method
- 1 February 1975
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 22 (1) , 359-363
- https://doi.org/10.1109/TNS.1975.4327662
Abstract
Tomographic scanners of the parallel beam and fan beam type have differences in the direction of sweep, r vs. ϕ respectively. This leads to different options in the "fill" of the sampling space, which may be important in accurate reconstruction. These differences are denoted in reference to the Radon integrational method of reconstruction. An algorithm using source angle gating of data from a fan beam scanner is given with a reconstruction from a simulation phantom scan which used discrete source and detector apertures with rotation smearing.Keywords
This publication has 3 references indexed in Scilit:
- Cross-sectional absorption density reconstruction for treatment planningPhysics in Medicine & Biology, 1974
- The Fourier reconstruction of a head sectionIEEE Transactions on Nuclear Science, 1974
- Three-dimensional Reconstruction from Radiographs and Electron Micrographs: Application of Convolutions instead of Fourier TransformsProceedings of the National Academy of Sciences, 1971