Material Science Plastic Deformation of Orthodontic Wires
- 1 September 1983
- journal article
- research article
- Published by SAGE Publications in Journal of Dental Research
- Vol. 62 (9) , 1016-1020
- https://doi.org/10.1177/00220345830620090401
Abstract
Theoretical predictions of the bending moments in the region of plastic behavior were accurate for beta titanium and stainless steel, but were consistently low in the far-elastic region for the three alloys studied.Keywords
This publication has 5 references indexed in Scilit:
- Flexure Modulus of Orthodontic Stainless Steel WiresJournal of Dental Research, 1981
- Force Systems from Orthodontic Appliances: An Analytical and Experimental ComparisonJournal of Biomechanical Engineering, 1980
- Measurement of Bending Deformation for Small Diameter Orthodontic WiresJournal of Dental Research, 1979
- Bending characteristics of nitinol wireAmerican Journal of Orthodontics, 1979
- Three-dimensional large displacement analysis of orthodontic appliancesJournal of Biomechanics, 1976