Development of a Loop-Mediated Isothermal Amplification Assay for Rapid Detection of BK Virus
- 1 May 2007
- journal article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 45 (5) , 1581-1587
- https://doi.org/10.1128/jcm.01024-06
Abstract
Loop-mediated isothermal amplification (LAMP) is a novel method for rapid amplification of DNA. Its advantages include rapidity and minimal equipment requirement. The LAMP assay was developed for BK virus (BKV), which is a leading cause of morbidity in renal transplant recipients. The characteristics of the assay, including its specificity and sensitivity, were evaluated. BKV LAMP was performed using various incubation times with a variety of specimens, including unprocessed urine and plasma samples. A ladder pattern on gel electrophoresis, typical of successful LAMP reactions, was observed specifically only for BKV and not for other viruses. The sensitivity of the assay with 1 h of incubation was 100 copies/tube of a cloned BKV fragment. Additionally, a positive reaction was visually ascertained by a simple color reaction using SYBR green dye. BKV LAMP was also successful for urine and plasma specimens without the need for DNA extraction. Due to its simplicity and specificity, the LAMP assay can potentially be developed for "point of care" screening of BKV.Keywords
This publication has 20 references indexed in Scilit:
- Development of the loop-mediated isothermal amplification method for rapid detection of cytomegalovirus DNAJournal of Virological Methods, 2006
- BK virus nephritis after renal transplantationKidney International, 2006
- Polyomavirus Allograft Nephropathy and Concurrent Acute Rejection: A Diagnostic and Therapeutic ChallengeAmerican Journal of Transplantation, 2004
- Correlates of Quantitative Measurement of BK Polyomavirus (BKV) DNA with Clinical Course of BKV Infection in Renal Transplant PatientsJournal of Clinical Microbiology, 2004
- Detection of Human Herpesvirus 7 DNA by Loop-Mediated Isothermal AmplificationJournal of Clinical Microbiology, 2004
- Rapid Diagnosis of Human Herpesvirus 6 Infection by a Novel DNA Amplification Method, Loop-Mediated Isothermal AmplificationJournal of Clinical Microbiology, 2004
- Polyomavirus BKThe Lancet Infectious Diseases, 2003
- Quantitative viral load monitoring and cidofovir therapy for the management of BK virus-associated nephropathy in children and adults1Transplantation, 2003
- Accelerated reaction by loop-mediated isothermal amplification using loop primersMolecular and Cellular Probes, 2002
- Detection of Loop-Mediated Isothermal Amplification Reaction by Turbidity Derived from Magnesium Pyrophosphate FormationBiochemical and Biophysical Research Communications, 2001