The effect of the phase of transmission on contrast agent echoes
- 1 July 1998
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 45 (4) , 872-875
- https://doi.org/10.1109/58.710539
Abstract
Ultrasound contrast agents consist of a gas bubble, encapsulated by a shell for stabilization. The shell dampens the fluctuations in the bubble radius when insonified. The detection of contrast microbubbles during a medical examination can indicate whether a region is perfused with blood. Here, the authors consider the effect of the phase of sonification signal on the backscatter by the bubble echo. By transmitting two short pulses of ultrasound with opposite phases, the authors demonstrate that a unique pair of echoes can be generated by a single microbubble, and that the properties of these echoes may be useful in the discrimination of bubble and tissue echoes. Specifically, the significant echo amplitude begins coincident with each transmitted rarefactional half-cycle, and the mean frequency of this echo depends on the transmitted phase. When rarefaction is transmitted first for a 2.25 MHz signal, the mean frequency is 0.8 MHz higher for an albumin-shelled bubble and 0.9 MHz higher for a lipid-shelled bubble. The experimental results agree with the predictions of the Gilmore-Akulichev equation.Keywords
This publication has 11 references indexed in Scilit:
- Intravenous Contrast Agent For Ultrasound Doppler: In Vivo Measurement Of Small Tumor Vessel Dose-responsePublished by Institute of Electrical and Electronics Engineers (IEEE) ,2005
- Simultaneous optical and acoustical observations of contrast agentsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Pulse inversion Doppler: a new method for detecting nonlinear echoes from microbubble contrast agentsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Some considerations on the measurements of mean frequency shift and integrated backscatter following administration of albunex®Ultrasound in Medicine & Biology, 1996
- Second harmonic imaging and harmonic Doppler measurements with AlbunexIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1995
- Higher harmonics of vibrating gas-filled microspheres. Part one: simulationsUltrasonics, 1994
- Ultrasound scattering properties of Albunex microspheresUltrasonics, 1993
- Second harmonic ultrasonic blood perfusion measurementUltrasound in Medicine & Biology, 1993
- Absorption and scatter of encapsulated gas filled microspheres: Theoretical considerations and some measurementsUltrasonics, 1992
- A theoretical study of cavitation generated by an extracorporeal shock wave lithotripterThe Journal of the Acoustical Society of America, 1989