Portable, Battery-Powered, Tungsten Coil Atomic Absorption Spectrometer for Lead Determinations
- 1 February 1996
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 50 (2) , 174-181
- https://doi.org/10.1366/0003702963906591
Abstract
A compact, inexpensive atomic absorption spectrometer has been designed, constructed, and evaluated for the determination of lead at the μg/L level. The new device is made feasible by the combination of a reliable tungsten coil atomizer, a miniature spectrometer/charge-coupled device combination mounted on a PC card, and a near-line background-correction method. The finished spectrometer can be powered by a normal 12-V car battery, controlled with a laptop computer, and transported in any automobile. The overall dimensions of the original prototype system are 19 in. × 8 in. × 3 in. (excluding the computer), and it has no moving parts. The total estimated cost of the system including the computer is less than $6000. The limit of detection for Pb is 20 pg (20-μL sample volume), the linear dynamic range is two orders of magnitude, and the precision for the technique is 5% RSD at concentrations ten times greater than the detection limit. The accuracy of the technique was determined with the use of NIST SRM #1579a “Powdered Lead-Based Paint” containing 11.995 wt % Pb and NIST SRM 955a “Lead in Blood” containing 54.43 μg/dL Pb. The accuracy for the paint sample was 95.1% (11.41 wt % found) with the use of the calibration curve method (aqueous standards) and 97.2% (11.66 wt % found) with the method of standard additions. The accuracy for the blood sample was 93.5% (50.9 μg/dL found) with the calibration curve method and 96.6% (56.3 μg/dL found) with the method of standard additions. The limiting source of noise for the instrument is detector noise, so that the performance of the device can be improved by increasing the optical throughput of the system.Keywords
This publication has 15 references indexed in Scilit:
- Determination of barium in waters by tungsten coil electrothermal atomic absorption spectrometryJournal of Analytical Atomic Spectrometry, 1994
- Determination of cadmium in biological materials by tungsten coil atomic absorption spectrometryJournal of Analytical Atomic Spectrometry, 1993
- Graphite furnace analysis—getting easier and achieving more?Analytica Chimica Acta, 1991
- Frontiers in elemental analysis by mass spectrometryAnalytica Chimica Acta, 1991
- Influence of coexisting analytes in atmospheric pressure ionization mass spectrometryAnalytical Chemistry, 1991
- A comparison of CCD and CID detection for atomic emission spectroscopySpectrochimica Acta Part B: Atomic Spectroscopy, 1989
- Applications of charge transfer devices in spectroscopyAnalytical Chemistry, 1988
- Simple low-cost tungsten-coil atomiser for electrothermal atomic absorption spectrometryJournal of Analytical Atomic Spectrometry, 1988
- Background correction errors originating from nonsimultaneous sampling for graphite furnace atomic absorption spectrometryAnalytical Chemistry, 1985
- Preparation of standard solutionsJournal of Chemical Education, 1973