Prolonged application of pressure in transluminal coronary angioplasty
- 1 January 1984
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Diagnosis
- Vol. 10 (3) , 213-219
- https://doi.org/10.1002/ccd.1810100305
Abstract
We investigated the morphologic structure and fluid content of atherosclerotic specimens of fresh human postmortem artery segments before and after application of a pressure of 5 atmospheres simulated by a weight of 5 kg per 1 cm2. After applying pressure in nonorganized atheromata, we noticed a marked reduction in thickness while in fibrotic atheromata we observed only smaller differences in thickness. Reduction in fluid content was significantly more pronounced in nonorganized atheromatous tissue. Reduction in thickness was closely related to reduction in weight (i e, fluid content). The time of pressure application necessary to achieve the optimal result averaged 60 sec. The conclusions drawn from these experiments were incorporated into clinical application of coronary angioplasty. Prolonged balloon inflation was applied to the last 400 out of a total of 600 coronary angioplasty procedures, performed between October 1977 and October 1983. Stenoses not sufficiently responsive to balloon inflation periods of 5–10 sec were exposed to periods of 60 sec (30–120 sec). The number of “non dilatable” stenoses was 15% with the standard short pressure procedure, but only 5% with the prolonged pressure application. No serious complications related to prolonged pressure application were observed. Thus, from experimental data and clinical experience the application of longer pressure periods appears justified and beneficial.Keywords
This publication has 7 references indexed in Scilit:
- Frequency in nonangioplasty patients of morphologic findings reported in coronary arteries treated with transluminal angioplastyThe American Journal of Cardiology, 1983
- The mechanisms of dilatation in transluminal coronary angioplasty. A postmortal studyThe American Journal of Cardiology, 1982
- The mechanism of balloon angioplasty.Radiology, 1980
- Transluminal angioplasty: correlation of morphologic and angiographic findings in an experimental model.Circulation, 1980
- Scanning electron microscopy after coronary transluminal angioplasty of normal canine coronary arteriesThe American Journal of Cardiology, 1980
- Evaluation of transluminal angioplasty of chronic coronary artery stenosis. Value and limitations assessed in fresh human cadaver hearts.Circulation, 1980
- Transluminal Treatment of Arteriosclerotic ObstructionCirculation, 1964