Hybrid Total Hip Arthroplasty
- 1 December 1996
- journal article
- presidential guest-speaker
- Published by Wolters Kluwer Health
- Vol. 333, 147???154
- https://doi.org/10.1097/00003086-199612000-00014
Abstract
A consecutive series of 125 hybrid total hip arthroplasties were performed in 120 patients by a single surgeon and were observed for an average of 8.6 years (range, 7–11 years). There were 38 men and 82 women with an average age of 71 years (range, 25–87 years) at the time of surgery. The diagnoses included primary and secondary osteoarthritis in 112 patients, osteonecrosis in 5 patients, and rheumatoid arthritis in 3 patients. All acetabular components were modular and had a Ti shell fixed with an average of 3 screws. The cemented femoral component was either Precoat® or Precoat Plus® with a 28-mm modular CoCr femoral head. The patients were prospectively observed clinically using the Harris hip score and radiographically using the Hip Society methods. Of the 125 total hip arthroplasties, 123 were followed for the entire observation period. The average preoperative Harris Hip Score was 37 (range, 15–55) and at the latest followup was 92 (range, 65–100). One acetabular component was revised for recurrent dislocations 3 years after surgery, and 1 stem was revised for mechanical loosening and 1 stem was radiographically loose. There was no evidence of cup migration of more than 1 mm. There were no radiolucencies around any of the screws. Two sockets had polyethylene wear of 2 mm. Localized pelvic osteolysis was noted in 5 hips (4%). The results of this study suggested that hybrid total hip replacement is an excellent procedure for reconstruction of the arthritic hip with minimal evidence of polyethylene wear and pelvic osteolysis.Keywords
This publication has 11 references indexed in Scilit:
- Total hip arthroplasty with use of so-called second-generation cementing techniques. A fifteen-year-average follow-up study.Journal of Bone and Joint Surgery, 1995
- Severe polyethylene wear in total hip arthroplastyThe Journal of Arthroplasty, 1994
- Severe osteolysis of the pelvic in association with acetabular replacement without cement.Journal of Bone and Joint Surgery, 1993
- Hybrid total hip replacement. A 6.5-year follow-up studyThe Journal of Bone and Joint Surgery. British volume, 1993
- Histological and radiographic assessment of well functioning porous-coated acetabular components. A human postmortem retrieval study.Journal of Bone and Joint Surgery, 1993
- Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic reviewThe Journal of Bone and Joint Surgery. British volume, 1992
- Total hip arthroplasty.Journal of Bone and Joint Surgery, 1978
- Ectopic Ossification Following Total Hip ReplacementJournal of Bone and Joint Surgery, 1973
- Traumatic Arthritis of the Hip after Dislocation and Acetabular FracturesJournal of Bone and Joint Surgery, 1969
- Nonparametric Estimation from Incomplete ObservationsJournal of the American Statistical Association, 1958