A study of chromium induced allergic contact dermatitis with 54 volunteers: implications for environmental risk assessment.
Open Access
- 1 June 1994
- journal article
- research article
- Published by BMJ in Occupational and Environmental Medicine
- Vol. 51 (6) , 371-380
- https://doi.org/10.1136/oem.51.6.371
Abstract
Over the past 60 years, dose-response patch test studies by various methods have been conducted in an attempt to identify the minimum elicitation threshold (MET) concentration of hexavalent chromium (Cr(VI)) that produces an allergic response in Cr(VI) sensitive subjects. These data are not adequate, however, to provide an accurate estimate of the MET because of the variability in the patch testing techniques and the variability in diagnostic criteria used. Furthermore, the data were not reported in terms of mass of allergen per surface area of skin (mg Cr/cm2-skin), which is necessary for conducting occupational or environmental health risk assessments. Thus the purpose of this study was to determine the MET (mg allergen/cm2) for Cr(VI) and trivalent chromium (Cr(III)) by patch testing techniques. A patch test method that delivers a controlled amount of allergen per surface area of skin was used. A group of 54 Cr(VI) sensitised volunteers were patch tested with serial dilutions of Cr(VI) and Cr(III) to determine the cumulative response rate at several concentrations. The results indicate that the 10% MET for Cr(VI) based on the cumulative response was 0.089 micrograms Cr(VI)/cm2-skin. Only one of the 54 volunteers may have responded to 33 micrograms Cr(III)/cm2-skin, otherwise Cr(III) was unable to produce allergic contact dermatitis in these highly sensitive volunteers. Two supplemental studies were also conducted to assess whether the surface area of the patch and the concentration of Cr(VI) in the patch (related to patch thickness) were likely to influence the results. The data from these studies were used to assess the risk of developing allergic contact dermatitis due to contact with Cr(VI) and Cr(III) in soil. The findings indicated that soil concentrations at least as high as 450 ppm Cr(VI) and 165,000 ppm Cr(III) should not pose an allergic contact dermatitis hazard for at least 99.99% of the people in the community who might be exposed.Keywords
This publication has 44 references indexed in Scilit:
- Using human sweat to extract chromium from chromite ore processing residue: Applications to setting health‐based cleanup levelsJournal of Toxicology and Environmental Health, 1993
- Risk assessment of the allergic dermatitis potential of environmental exposure to hexavalent chromiumJournal of Toxicology and Environmental Health, 1993
- Review of the allergic contact dermatitis hazard posed by chromium‐contaminated soil: Identifying a “safe” concentrationJournal of Toxicology and Environmental Health, 1992
- Influence of area of application of allergen on sensitization in contact dermatitisContact Dermatitis, 1992
- An Assessment and Quantitative Uncertainty Analysis of the Health Risks to Workers Exposed to Chromium Contaminated SoilsToxicology and Industrial Health, 1991
- Preliminary studies of the TRUE Test patch test system in the United StatesJournal of the American Academy of Dermatology, 1989
- Prevalence and relevance of allergic reactions in patients patch tested in North America—1984 to 1985Journal of the American Academy of Dermatology, 1989
- Easier patch testing with TRUE TestJournal of the American Academy of Dermatology, 1989
- Angry back or the excited skin syndrome: A prospective studyJournal of the American Academy of Dermatology, 1983
- The Identification of Contact Allergens by Human AssayJournal of Investigative Dermatology, 1966