Dose Reduction in Multislice Computed Tomography
- 1 January 2005
- journal article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 29 (1) , 140-147
- https://doi.org/10.1097/01.rct.0000151188.72850.0d
Abstract
Evaluation of the attenuation-based on-line modulation of tube current on multislice computed tomography (CT) to explore the potential of this dose-saving technique. Fifty-five patients with follow-up CT examinations were scanned without and with a CARE Dose (Siemens Medical Solutions, Erlangen, Germany). The applied dose, image noise, and subjective image quality were evaluated. The reduction in patient exposure was determined by obtaining the effective milliamperes per second for each reconstructed scan and the absolute dosage requirement for the whole scan. The dose reduction achieved by applying the attenuation-based on-line modulation of tube current was 29.4% +/- 3.1% (P=0.002) for all scans, 30.5% +/- 3.2% (P=0.002) for the thorax scans, 29.7% +/- 2.9% (P=0.002) for the abdomen scans, and 28.7% +/- 2.7% (P=0.003) for the thorax and abdomen scans together. No significant restrictions in image quality were observed. Remarkable dose reduction can be obtained using the attenuation-based on-line modulation of tube current on multislice CT without compromising image quality.Keywords
This publication has 11 references indexed in Scilit:
- Spiral CT and radiation doseEuropean Journal of Radiology, 2003
- Radiation Exposure at Chest CT: A Statement of the Fleischner SocietyRadiology, 2003
- Dose optimization in pediatric CT: current technology and future innovationsPediatric Radiology, 2002
- Current development of cardiac imaging with multidetector-row CTEuropean Journal of Radiology, 2000
- Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regionsEuropean Radiology, 2000
- Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studiesMedical Physics, 1999
- Dose reduction in CT by anatomically adapted tube current modulation. II. Phantom measurementsMedical Physics, 1999
- Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadaversEuropean Radiology, 1999
- Das „Smart-Scan”-Verfahren der Spiral-Computertomographie: Eine neue Methode der DosisreduktionRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1996
- Anatomisch adaptierte Variation des Röhrenstroms bei der CTRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1995