Comparison of Naive Sixth-Grade Children With Trained Professionals in the Use of an Automated External Defibrillator
- 19 October 1999
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 100 (16) , 1703-1707
- https://doi.org/10.1161/01.cir.100.16.1703
Abstract
Background—Survival after out-of-hospital cardiac arrest (OHCA) is strongly influenced by time to defibrillation. Wider availability of automated external defibrillators (AEDs) may decrease response times but only with increased lay use. Consequently, this study endeavored to improve our understanding of AED use in naive users by measuring times to shock and appropriateness of pad location. We chose sixth-grade students to simulate an extreme circumstance of unfamiliarity with the problem of OHCA and defibrillation. The children’s AED use was then compared with that of professionals. Methods and Results—With the use of a mock cardiac arrest scenario, AED use by 15 children was compared with that of 22 emergency medical technicians (EMTs) or paramedics. The primary end point was time from entry onto the cardiac arrest scene to delivery of the shock into simulated ventricular fibrillation. The secondary end point was appropriateness of pad placement. All subject performances were videotaped to assess safety of use and compliance with AED prompts to remain clear of the mannequin during shock delivery. Mean time to defibrillation was 90±14 seconds (range, 69 to 111 seconds) for the children and 67±10 seconds (range, 50 to 87 seconds) for the EMTs/paramedics (PConclusions—During mock cardiac arrest, the speed of AED use by untrained children is only modestly slower than that of professionals. The difference between the groups is surprisingly small, considering the naïveté of the children as untutored first-time users. These findings suggest that widespread use of AEDs will require only modest training.Keywords
This publication has 14 references indexed in Scilit:
- Low‐Energy Impedance‐Compensating Biphasic Waveforms Terminate Ventricular Fibrillation at High Rates in Victims of Out‐of‐Hospital Cardiac ArrestJournal of Cardiovascular Electrophysiology, 1997
- High Discharge Survival Rate After Out-of-Hospital Ventricular Fibrillation With Rapid Defibrillation by Police and ParamedicsAnnals of Emergency Medicine, 1996
- Computational studies of transthoracic and transvenous defibrillation in a detailed 3-D human thorax modelIEEE Transactions on Biomedical Engineering, 1995
- Student nurses can defibrillate within 90 secondsResuscitation, 1994
- Sudden Cardiac Death and National HealthPacing and Clinical Electrophysiology, 1993
- Encouraging early defibrillation: The American Heart Association and automated external defibrillatorsAnnals of Emergency Medicine, 1990
- Cardiac arrest and resuscitation: A tale of 29 citiesAnnals of Emergency Medicine, 1990
- Cost-effectiveness of defibrillation by emergency medical techniciansThe American Journal of Emergency Medicine, 1988
- Lay person use of automatic external defibrillationAnnals of Emergency Medicine, 1987
- Cardiac arrest treated with a new automatic external defibrillator by out-of-hospital first respondersThe American Journal of Cardiology, 1986