A Hall effect transducer for measuring length changes in mammalian diaphragm
- 1 August 1983
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 55 (2) , 635-641
- https://doi.org/10.1152/jappl.1983.55.2.635
Abstract
When a conductor through which a current is flowing is brought into a magnetic field, the isopotential lines are distorted (E. H. Hall, 1879). When a constant current is made to flow through a Hall generator, the measured voltage perpendicular to the current flow can be made to vary by altering the distance between a permanent magnet and a Hall generator. A length transducer useful for measuring length changes in the diaphragm of a dog is made by connecting a commercially available Hall generator to a Plexiglas plate (5 X 10 X 3 mm, 0.5 g), and suturing the plate to the surface of the muscle. A permanent magnet (20 X 10 X 4 mm, 1.5 g) is attached to the diaphragm at a distance of 2 or 3 cm along the expected direction of length change. Fine wires from the terminals of the Hall generator are connected to an external constant-current source and to solid-state circuitry which provides amplification, linearization, and temperature compensation of the output signal. Model experiments indicate that the length measurements may be accurate within 5% if the distance between the magnet and Hall generator is greater than 5 mm. With this type of transducer measurements of segmental length changes in the diaphragm of an anesthetized dog have been successfully recorded.This publication has 13 references indexed in Scilit:
- Mechanics of the canine diaphragmJournal of Applied Physiology, 1976
- Alterations in left ventricular dimensions and mural force following coronary occlusionAmerican Journal of Physiology-Legacy Content, 1968
- Evaluation of myocardial force-velocity relation in closed-chest dogsAmerican Journal of Physiology-Legacy Content, 1968
- A portable, simple sonomicrometer.Journal of Applied Physiology, 1967
- Measurement of the shortening of cardiac fibers in manThe American Journal of Cardiology, 1967
- Improved technique for estimating pleural pressure from esophageal balloonsJournal of Applied Physiology, 1964
- Left Ventricular Dimensions Recorded by SonocardiometryCirculation Research, 1956
- Right Ventricular ContractionAmerican Journal of Physiology-Legacy Content, 1956
- Initial Phase of Ventricular Systole: Asynchronous ContractionAmerican Journal of Physiology-Legacy Content, 1955
- On a New Action of the Magnet on Electric CurrentsAmerican Journal of Mathematics, 1879