Non-invasive measurement of cardiac output by a single breath constant expiratory technique.
Open Access
- 1 February 1984
- Vol. 39 (2) , 107-113
- https://doi.org/10.1136/thx.39.2.107
Abstract
A new single breath test has been developed that measures pulmonary blood flow (Qc) and pulmonary tissue volume by using the fact that Qc is proportional to the relationship between the absorption rate of acetylene (C2H2) from the alveolar gas and the rate of change of lung volume during constant expiratory flow. To make these measurements a bag in bottle system with a rolling seal spirometer, a mass spectrometer, and a minicomputer with analogue to digital conversion have been used. Qc was compared with cardiac output measured by the thermodilution technique in 20 patients with cardiac disease; some also had mild chronic obstructive pulmonary disease. The mean (SD) resting Qc for the group was 5.27 (1.22) l/min and the cardiac output measured by thermodilution was 5.30 (1.31) l/min. The mean difference between the two estimations of cardiac output was 0.03 l and the standard deviation of this difference was 0.76 l. The Qc technique was not successful in patients with an FEV1/FVC less than 60%, but seemed to be accurate in those with higher FEV1/FVC values. Correction of Qc for the effect of venous admixture in 14 patients resulted in an average 19% overestimation of cardiac output (6.01 (2.52) l/min v 5.05 (1.64) l/min). It is concluded that cardiac output can be accurately measured in patients with cardiac or mild pulmonary disease. No correction for venous admixture due to ventilation-perfusion mismatch was necessary in these patients, presumably because the large breath used by the technique overcomes most mild ventilation-perfusion maldistribution. These findings, in addition to the non-invasive nature of the technique, suggest potential value for the measurement of cardiac output in various clinical conditions.Keywords
This publication has 17 references indexed in Scilit:
- Superiority of two-dimensional measurement of aortic vessel diameter in doppler echocardiographic estimates of left ventricular stroke volumeJournal of the American College of Cardiology, 1985
- Theoretical basis of single breath gas absorption testsJournal of Mathematical Biology, 1982
- Use of equilibrium (gated) radionuclide ventriculography to quantitate left ventricular output in patients with and without left-sided valvular regurgitation.Circulation, 1981
- Single-exhalation method for study of lobar and segmental lung function by mass spectrometry in manRespiration Physiology, 1980
- Transcutaneous Doppler method of measuring cardiac output—IIThe American Journal of Cardiology, 1980
- Vertical Distributions of Pulmonary Diffusing Capacity and Capillary Blood Flow in ManJournal of Clinical Investigation, 1973
- Determination of Left Ventricular Volumes by UltrasoundCirculation, 1971
- Left Ventricular Volumes and Ejection Fraction by EchocardiographyCirculation, 1971
- A Standardized Breath Holding Technique for the Clinical Measurement of the Diffusing Capacity of the Lung for Carbon Monoxide 1Journal of Clinical Investigation, 1957
- Measurements of the Blood Flow through the Lungs of Man1Skandinavisches Archiv Für Physiologie, 1912