Carbon Composite Microelectrodes: Charge Percolation and Electroanalytical Performance
- 26 November 2003
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (3) , 503-512
- https://doi.org/10.1021/ac034536p
Abstract
Microelectrodes based on two different epoxy−graphite composites (Araldite-M/HY5162 and Araldite-PY302-2/HY943) that are compatible with organic solvents have been developed and characterized. The variation in the bulk conductivity with graphite particle loading is described by percolation theory and indicates that the particles interact strongly with one another. The percolation threshold is 52% v/v loading of graphite, and this composite exhibits a bulk conductivity of 15 S m-1. Microdisk electrodes of 25-μm diameter were produced by first etching a microcavity at the tip of a platinum microelectrode, which was then packed with a composite containing 60% v/v graphite so as to optimize both electrical conductivity and the electrode stability in acetonitrile and methanol solutions. Solution phase voltammetry of ferrocene is nearly ideal, and the responses are dominated by radial diffusion (slow scan rates) and semi-infinite linear diffusion (fast scan rates). The microelectrodes display high signal-to-noise ratios, good sensitivity, and low detection limits. The response times given by the product of the resistance, R, and capacitance, C, are 7.5 × 10-4 and 1.4 × 10-1 s for the Araldite M and PY302-2 composites, respectively. Although these response times are significantly slower than those associated with microelectrodes based on carbon fibers or metal wires, they are sufficient for time-resolved electroanalytical applications. The long response times arise from the large composite resistances, 3.1 × 1011 and 8.3 × 1011 Ω cm-2 for Araldite M and PY302-2, respectively. Voltammetry of ferrocene in the absence of deliberately added supporting electrolyte is also reported. Significantly, indistinguishable slopes and intercepts for a calibration curve of peak current vs ferrocene concentration where 2 < [ferrocene] < 50 μM are obtained in the presence and absence of supporting electrolyte.Keywords
This publication has 29 references indexed in Scilit:
- On the microelectrode behaviour of graphite–epoxy composite electrodesElectrochemistry Communications, 2002
- Fabrication of carbon microelectrodes with an effective radius of 1 nmElectrochemistry Communications, 2001
- Effect of Electrode Density of States on the Heterogeneous Electron-Transfer Dynamics of Osmium-Containing MonolayersJournal of the American Chemical Society, 2000
- Enzyme-Amplified Amperometric Detection of Hybridization and of a Single Base Pair Mutation in an 18-Base Oligonucleotide on a 7-μm-Diameter MicroelectrodeJournal of the American Chemical Society, 1999
- Membrane-assembly of carbon microelectrodes for the electrochemical study of redox proteinsAnalytica Chimica Acta, 1997
- Determination of organonitriles using enzyme-based selectivity mechanisms. 2. A nitrilase-modified glassy carbon microelectrode sensor for benzonitrileAnalytical Chemistry, 1995
- Temperature-dependent resistivity and conduction mechanism in carbon particle-filled polymersJournal of Materials Science, 1992
- Nonlinear regression analysis of steady‐state voltammograms obtained at microelectrodesElectroanalysis, 1989
- The Electrochemical Behavior of Graphite Fiber‐Epoxy Composite Electrodes Containing Varying Fiber OrientationsJournal of the Electrochemical Society, 1988
- Graphitized carbon black in polyethylene as an electrochemical sensorAnalytica Chimica Acta, 1985