Hepatic T2‐weighted MRI: A prospective comparison of sequences, including breath‐hold, half‐Fourier turbo spin echo (HASTE)
- 1 May 1998
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 8 (3) , 642-649
- https://doi.org/10.1002/jmri.1880080319
Abstract
The purpose of this study was to quantitatively compare the hepatic contrast characteristics of conventional spin‐echo (CSE) and fast spin‐echo (FSE) sequences with breath‐hold T2‐weighted images acquired with half‐Fourier turbo spin echo (HASTE). Forty‐five patients were examined with a phased‐array surface coil. Nineteen patients had focal hepatic lesions, including eight malignant tumors, 10 cavernous hemangiomas, and one hepatic adenoma. Twenty‐six patients had no focal hepatic lesions. T2‐weighted images with comparable TE were acquired with CSE, FSE, and HASTE pulse sequences. Signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR) for liver, spleen, and lesions were measured. FSE demonstrated significantly better quantitative performance than CSE for liver‐spleen CNR (P = .0084). No statistically significant difference was demonstrated between FSE and CSE for liver or spleen SNR. FSE demonstrated clear scan time and resolution advantages over CSE. HASTE performed significantly poorer than CSE and FSE for liver‐spleen CNR (P < .0001), liver SNR (P = .0002 for CSE and P < .0001 for FSE), and spleen SNR (P < .0001). Optimized FSE images with a short echo train length performed comparably to CSE images of equivalent TE. Liver‐lesion CNR was suppressed on HASTE images, suggesting that long echo train length FSE sequences could diminish solid lesion detection compared to CSE and short echo train length FSE.Keywords
This publication has 31 references indexed in Scilit:
- Comparison of breath-hold fast spin-echo and conventional spin-echo pulse sequences for T2-weighted MR imaging of liver lesions.Radiology, 1995
- Echoplanar MR imaging of the liver in patients with focal hepatic lesions: quantitative analysis of images made with various pulse sequences.American Journal of Roentgenology, 1994
- Hepatic hemangiomas and malignant tumors: improved differentiation with heavily T2-weighted conventional spin-echo MR imaging.Radiology, 1994
- Abdominal MR imaging: evaluation of a fast spin-echo sequence.Radiology, 1994
- The pelvis: T2-weighted fast spin-echo MR imaging.Radiology, 1992
- Fast spin-echo MR imaging of the brain and spine: current concepts.American Journal of Roentgenology, 1992
- Contrast manipulation and artifact assessment of 2D and 3D RARE sequencesMagnetic Resonance Imaging, 1990
- Contrast optimization for the detection of focal hepatic lesions by MR imaging at 1.5 TAmerican Journal of Roentgenology, 1987
- Liver metastasis detection: comparative sensitivities of MR imaging and CT scanning.Radiology, 1987
- Magnetic resonance imaging of cavernous hemangioma of the liver: tissue-specific characterizationAmerican Journal of Roentgenology, 1985