Motion‐insensitive, steady‐state free precession imaging
- 1 December 1990
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 16 (3) , 444-459
- https://doi.org/10.1002/mrm.1910160311
Abstract
Steady‐state free precession (SSFP) pulse sequences employing gradient reversal echoes and short repetition time (TR) between successive rf excitation pulses offer high signal‐to‐noise ratio per unit time. However, SSFP sequences are very sensitive to motion. A new SSFP method is presented which avoids the image artifacts and loss of signal intensity due to motion. The pulse sequence is designed so that the time integral of each of the three gradients is zero over each TR time interval. The signal then consists of numerous echoes which are superimposed. These echoes are isolated by combining the data from N different scans. In each scan a specific phase shift is added during every TR interval. Each of these N isolated echoes produces a motion‐insensitive, artifact‐free image. Because all the echoes are sampled simultaneously, the signal‐to‐noise ratio per unit time in this SSFP method is higher than in existing SSFP techniques which sample only one echo at a time. The new method was implemented and used to produce both two‐ and three‐dimensional images of the head and cervical spin of a human patient. In these images the high signal intensity of cerebrospinal fluid is preserved regardless of its motion. Further work is required to evaluate the imaging parameters (TR, TE, rf tip angle) so as to give optimal tissue contrast for the various echoes. © 1990 Academic Press, Inc.Funding Information
- Toshiba Corporation
- Division of Research Resources, National Institutes of Health (SO7-RR05598)
This publication has 17 references indexed in Scilit:
- Steady-state free precession imaging in the presence of motion: application for improved visualization of the cerebrospinal fluid.Radiology, 1990
- MRI of “diffusion” in the human brain: New results using a modified CE‐FAST sequenceMagnetic Resonance in Medicine, 1989
- The steady-state signals in short-repetition-time sequencesJournal of Magnetic Resonance (1969), 1989
- Elimination of transverse coherences in FLASH MRIMagnetic Resonance in Medicine, 1988
- The application of steady-state free precession in rapid 2DFT NMR imaging: FAST and CE-FAST sequencesMagnetic Resonance Imaging, 1988
- FADE–A new fast imaging sequenceMagnetic Resonance in Medicine, 1988
- An analysis of fast imaging sequences with steady‐state transverse magnetization refocusingMagnetic Resonance in Medicine, 1988
- Fast Imaging of CSF Flow/Motion Patterns Using Steady-State Free Precession (SSFP)Investigative Radiology, 1987
- The application of steady‐state free precession to the study of very slow fluid flowMagnetic Resonance in Medicine, 1986
- Image formation by nuclear magnetic resonance: The sensitive-point methodJournal of Applied Physics, 1976