Doppler Color Flow Image Size: Dependence on Instrument Settings
- 1 May 1991
- journal article
- Published by Wiley in Echocardiography
- Vol. 8 (3) , 319-327
- https://doi.org/10.1111/j.1540-8175.1991.tb01195.x
Abstract
Doppler color flow imaging provides important qualitative information about the location and spatial distribution of intracardiac blood flow. However, the effect of instrument-related variables on the size of color Doppler images requires further definition. Flow of a silicone particle solution was established in a tube or cylinder and scanned as color gain, pulse repetition frequency, depth, and transducer frequency were varied. The diameter of Doppler color flow images were measured during constant laminar or disturbed flow parallel to the ultrasound beam and during laminar flow perpendicular to the ultrasound beam. The diameter of color Doppler images of laminar flow perpendicular and parallel to the beam varied directly with color gain. Diameter varied inversely with transducer frequency for laminar flow parallel to the transducer and inversely with pulse repetition frequency for laminar flow perpendicular to the transducer. The diameter of laminar flow parallel to the transducer varied directly with the depth of the flow area below the transducer. The size of the color flow dropout of laminar flow exactly perpendicular to the ultrasound beam varied directly with transducer frequency and inversely with gain. During disturbed flow parallel to the transducer, the diameter of the image varied directly with gain and inversely with transducer frequency and pulse repetition frequency. Instrument settings have a significant impact on the size of color Doppler images. Understanding the effects of changes in these variables is important for reliable diagnostic use of Doppler color flow imaging. (ECHOCARDIOGRAPHY, Volume 8, May 1991)Keywords
This publication has 12 references indexed in Scilit:
- Sources of variability for doppler color flow mapping of regurgitant jets in an animal model of mitral regurgitationJournal of the American College of Cardiology, 1989
- Doppler color flow mapping of simulated in vitro regurgitant jets: Evaluation of the effects of orifice size and hemodynamic variablesJournal of the American College of Cardiology, 1989
- Two-Dimensional Color Doppler Estimation of the Severity of Atrioventricular Valve Regurgitation: Important Effects of Instrument Gain Setting, Pulse Repetition Frequency, and Carrier FrequencyJournal of the American Society of Echocardiography, 1989
- Quantifying valvular regurgitation. Limitations and inherent assumptions of Doppler techniques.Circulation, 1988
- Computer analysis of Doppler color flow mapping images for quantitative assessment of in vitro fluid JetsJournal of the American College of Cardiology, 1988
- Observer variability in the quantitation of Doppler color flow jet areas for mitral aortic regurgitationJournal of the American College of Cardiology, 1988
- Technical and biologic sources of variability in the mapping of aortic, mitral and tricuspid color flow jetsThe American Journal of Cardiology, 1987
- Calibration of color Doppler flow mapping during extreme hemodynamic conditions in vitro: a foundation for a reliable quantitative grading system for aortic incompetence.Circulation, 1987
- Reliability and reproducibility of two dimensional echocardiographic measurement of the stenotic mitral valve orifice areaThe American Journal of Cardiology, 1979
- Determination of Mitral Valve Area by Cross-Sectional EchocardiographyAnnals of Internal Medicine, 1978