Combined infrared multiphoton dissociation and electron capture dissociation with a hollow electron beam in Fourier transform ion cyclotron resonance mass spectrometry
- 27 June 2003
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 17  (15) , 1759-1768
- https://doi.org/10.1002/rcm.1118
Abstract
An electron injection system based on an indirectly heated ringâshaped dispenser cathode has been developed and installed in a 7 Tesla Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. This new hardware design allows highârate electron capture dissociation (ECD) to be carried out by a hollow electron beam coaxial with the ion cyclotron resonance (ICR) trap. Infrared multiphoton dissociation (IRMPD) can also be performed with an onâaxis IRâlaser beam passing through a hole at the centre of the dispenser cathode. Electron and photon irradiation times of the order of 100 ms are required for efficient ECD and IRMPD, respectively. As ECD and IRMPD generate fragments of different types (mostly c, z and b, y, respectively), complementary structural information that improves the characterization of peptides and proteins by FTICR mass spectrometry can be obtained. The developed technique enables the consecutive or simultaneous use of the ECD and IRMPD methods within a single FTICR experimental sequence and on the same ensemble of trapped ions in multistage tandem (MS/MS/MS or MSn) mass spectrometry. Flexible changing between ECD and IRMPD should present advantages for the analysis of protein digests separated by liquid chromatography prior to FTICRMS. Furthermore, ion activation by either electron or laser irradiation prior to, as well as after, dissociation by IRMPD or ECD increases the efficiency of ion fragmentation, including the wâtype fragment ion formation, and improves sequencing of peptides with multiple disulfide bridges. The developed instrumental configuration is essential for combined ECD and IRMPD on FTICR mass spectrometers with limited access into the ICR trap. Copyright © 2003 John Wiley & Sons, Ltd.Keywords
This publication has 22 references indexed in Scilit:
- Liquid chromatography and electronâcapture dissociation in Fourier transform ion cyclotron resonance mass spectrometryRapid Communications in Mass Spectrometry, 2002
- Blackbody infrared radiative dissociation of larger (42 kDa) multiply charged proteinsInternational Journal of Mass Spectrometry, 2001
- High-Sensitivity Electron Capture Dissociation Tandem FTICR Mass Spectrometry of Microelectrosprayed PeptidesAnalytical Chemistry, 2001
- Packed Capillary Reversed-Phase Liquid Chromatography with High-Performance Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry for ProteomicsAnalytical Chemistry, 2001
- Evolution of esiâmass spectrometry and fourier transform ion cyclotron resonance for proteomics and other biological applicationsInternational Journal of Mass Spectrometry, 2000
- Electron Capture Dissociation for Structural Characterization of Multiply Charged Protein CationsAnalytical Chemistry, 2000
- Identification of Intact Proteins in Mixtures by Alternated Capillary Liquid Chromatography Electrospray Ionization and LC ESI Infrared Multiphoton Dissociation Fourier Transform Ion Cyclotron Resonance Mass SpectrometryAnalytical Chemistry, 1999
- Fourier transform ion cyclotron resonance mass spectrometry: A primerMass Spectrometry Reviews, 1998
- Infrared Multiphoton Dissociation of Large Multiply Charged Ions for Biomolecule SequencingAnalytical Chemistry, 1994
- Sustained off-resonance irradiation for collision-activated dissociation involving Fourier transform mass spectrometry. Collision-activated dissociation technique that emulates infrared multiphoton dissociationAnalytica Chimica Acta, 1991