Analysis of flow effects in echo‐planar imaging
- 1 May 1992
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 2 (3) , 285-293
- https://doi.org/10.1002/jmri.1880020306
Abstract
The effects on the phase of spins moving during echo-planar imaging (EPI) acquisition were studied. Standard single-shot and interleaved multishot blipped EPI acquisitions were considered, assuming either high gradient strength and slew rates or standard gradient strength and slew rates. A spiral k-space trajectory was also considered. Flow components in the section-select and phase- and frequency-encoding directions were analyzed separately. While the effect of flow in the section-select direction is identical to that in a standard two-dimensional Fourier transform (2DFT) acquisition, flow in the phase- or frequency-encoding directions can have substantial effects on the image, different from that in 2DFT imaging. The magnitude of these effects, which include displacement, distortion, and/or ghosting of vascular structures, is analyzed and predicted for a given velocity and direction of flow, the specific acquisition sequence, and the strength and slew rate of the gradients. For example, 50-cm/sec flow along the phase-encoding direction can cause a blurring of 1.25 cm full width at half maximum for blipped EPI with high-strength gradients, assuming a 40-cm field of view and 64 × 64 matrix.Keywords
This publication has 14 references indexed in Scilit:
- Normal flow patterns of intracranial and spinal cerebrospinal fluid defined with phase-contrast cine MR imaging.Radiology, 1991
- Spatial misregistration of vascular flow during MR imaging of the CNS: cause and clinical significance.American Journal of Roentgenology, 1990
- Rapid MR imaging of blood flow with a phase-sensitive, limited-flip-angle, gradient recalled pulse sequence: preliminary experience.Radiology, 1990
- Echo‐planar high‐resolution flow velocity mappingMagnetic Resonance in Medicine, 1989
- A method for reducing motion induced errors in T 2 -weighted magnetic resonance imagingMedical Physics, 1987
- Improving MR image quality in the presence of motion by using rephasing gradientsAmerican Journal of Roentgenology, 1987
- Human brain motion and cerebrospinal fluid circulation demonstrated with MR velocity imaging.Radiology, 1987
- Magnetic resonance angiography.Radiology, 1986
- Measurement of Flow with NMR Imaging Using a Gradient Pulse and Phase Difference TechniqueJournal of Computer Assisted Tomography, 1984
- A flow velocity zeugmatographic interlace for NMR imaging in humansMagnetic Resonance Imaging, 1982