The Dose-Response Relation of Intrathecal Fentanyl for Labor Analgesia
- 1 February 1998
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 88 (2) , 355-361
- https://doi.org/10.1097/00000542-199802000-00014
Abstract
Background: This study determined the dose-response relation of intrathecal fentanyl for labor analgesia and described the onset, duration, and quality of analgesia when used as the sole analgesic. Methods: Eighty-four parturients in active labor who requested analgesia were randomized to one of seven treatment groups. They received 5-45 microg intrathecal fentanyl as part of a combined spinal-epidural technique. Visual analog pain scores were recorded before and at intervals after injection patients requested additional analgesia. The occurrence and severity of pruritus, nausea, and vomiting were also recorded. Maternal blood pressure was recorded before injection and at intervals after injection. Fetal heart rate was recorded before and 30 min after injection. Results: By 5 min after injection, pain scores were significantly different among groups (P < 0.001). Mean duration of analgesia increased to 89 min as the dose increased to 25 microg. Maternal diastolic blood pressure was significantly lower 10 and 30 min after injection. There was no difference among groups in the incidence of pruritus; nausea and vomiting were uncommon. Fetal heart rates did not change after injection. A dose-response curve indicates that the median effective dose of intrathecal fentanyl for labor analgesia is 14 microg (95% confidence interval, 13-15 microg). Conclusions: Intrathecal fentanyl produces rapid, profound labor analgesia with minimal side effects. These data indicate that there is little benefit to increasing the dose beyond 25 microg when it is used as the sole agent for intrathecal labor analgesia.Keywords
This publication has 7 references indexed in Scilit:
- Determination of the Dose-Response Relationship for Intrathecal Sufentanil in Laboring PatientsAnesthesia & Analgesia, 1997
- Maternal Posture Influences the Extent of Sensory Block Produced by Intrathecal Dextrose-Free Bupivacaine with Fentanyl for Labor AnalgesiaAnesthesia & Analgesia, 1996
- Hemodynamic effects of intrathecal fentanyl in nonlaboring term parturientsJournal of Clinical Anesthesia, 1996
- Randomised comparison of combined spinal-epidural and standard epidural analgesia in labourThe Lancet, 1995
- Uterine Hyperactivity after Intrathecal Injection of Fentanyl for Analgesia during LaborAnesthesiology, 1994
- Comparison Among Intrathecal Fentanyl, Meperidine, and Sufentanil for Labor AnalgesiaAnesthesia & Analgesia, 1992
- Intrathecal Narcotics for Labor RevisitedAnesthesia & Analgesia, 1989