The design and use of an instrumented mG2 capsule filling machine simulator
- 1 April 1982
- journal article
- Published by Oxford University Press (OUP) in Journal of Pharmacy and Pharmacology
- Vol. 34 (4) , 230-235
- https://doi.org/10.1111/j.2042-7158.1982.tb04233.x
Abstract
The problems of instrumenting a continuous motion dosator nozzle capsule filling machine (mG2 type) are discussed and the construction of an mG2 simulator is described. A standard filling turret is employed with mechanical modification so that the dosator does not rotate. This allows instrumentation in the form of a strain gauged dosator piston, to measure compression and ejection stresses during filling, as well as distance transducers, to measure the corresponding piston and dosator movements. An experimental method is described for using this machine to study the filling of lactose powders.Keywords
This publication has 5 references indexed in Scilit:
- Simultaneous measurement of force and displacement in an automatic capsule filling machineInternational Journal of Pharmaceutics, 1980
- Instrumentation of an Automatic Capsule-Filling MachineJournal of Pharmaceutical Sciences, 1977
- Un nouveau manuscrit de La Chastelaine de VergyRomania, 1977
- The instrumentation of a Zanasi LZ/64 capsule filling machineJournal of Pharmacy and Pharmacology, 1975
- The Physics of Tablet Compression*Journal of the American Pharmaceutical Association (Scientific ed.), 1954