Validation of Accuracy-based Amino Acid Reference Materials in Dried-Blood Spots by Tandem Mass Spectrometry for Newborn Screening Assays
- 1 August 1999
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 45 (8) , 1269-1277
- https://doi.org/10.1093/clinchem/45.8.1269
Abstract
Background: Advances in technology and the earlier release of newborns from hospitals have pressed the demand for accurate calibration and improved interlaboratory performance for newborn screening tests. As a first step toward standardization of newborn screening aminoacidopathy tests, we have produced six-pool sets of multianalyte dried-blood-spot amino acid reference materials (AARMs) containing predetermined quantities of five amino acids. We describe here the production of the AARMs, validation of their amino acid contents, and characterization of their homogeneity and their stability in storage.Methods: To each of six portions of a pool of washed erythrocytes suspended in serum we added Phe (0–200 mg/L), Leu (0–200 mg/L), Met (0–125 mg/L), Tyr (0–125 mg/L), and Val (0–125 mg/L). Six-pool sets (1300) were prepared, dried, and packaged. We used isotope-dilution mass spectrometry to estimate the endogenous amino acid concentrations of the AARMs and validate their final amino acid concentrations. We used additional tandem mass spectrometry analyses to examine the homogeneity of amino acid distribution in each AARM, and HPLC analyses to evaluate the stability of the amino acid contents of the AARMs.Results: The absolute mean biases across the analytic range for five amino acids were 2.8–9.4%. One-way ANOVAs of the homogeneity results predicted no statistically significant differences in amino acid concentrations within the blood spots or within the pools (P >0.05). Regression slopes (0 ± 0.01) for amino acid concentrations vs storage times and their P values (>0.05) showed no evidence of amino acid degradation at ambient temperatures, 4 °C, or −20 °C during the intervals tested.Conclusion: The validation, homogeneity, and stability of these blood spots support their use as a candidate national reference material for calibration of assays that measure amino acids in dried-blood spots.Keywords
This publication has 14 references indexed in Scilit:
- Use of phenylalanine-to-tyrosine ratio determined by tandem mass spectrometry to improve newborn screening for phenylketonuria of early discharge specimens collected in the first 24 hoursClinical Chemistry, 1998
- Preparation of the first European working standard for phenylalanine determination in dried blood spotsJournal of Medical Screening, 1998
- Electrospray ionization mass spectrometry for the quantitation of albumin in human serumJournal of the American Society for Mass Spectrometry, 1997
- Isotope dilution--mass spectrometric quantification of specific proteins: model application with apolipoprotein A-IClinical Chemistry, 1996
- Guidelines for the Retention, Storage, and Use of Residual Dried Blood Spot Samples after Newborn Screening Analysis: Statement of the Council of Regional Networks for Genetic ServicesBiochemical and Molecular Medicine, 1996
- Rapid diagnosis of homocystinuria and other hypermethioninemias from newborns' blood spots by tandem mass spectrometryClinical Chemistry, 1996
- Synthesis of a Fluorescent Derivatizing Reagent, 6-Aminoquinolyl-N-Hydroxysuccinimidyl Carbamate, and Its Application for the Analysis of Hydrolysate Amino Acids via High-Performance Liquid ChromatographyAnalytical Biochemistry, 1993
- Determination of “free” glycerol in human serum reference materials by isotope-dilution gas chromatography—mass spectrometryJournal of Chromatography B: Biomedical Sciences and Applications, 1992
- Stability of amino acids and galactose in the newborn screening filter paper blood specimenThe Journal of Pediatrics, 1985
- Determination of steroid hormones in a human-serum reference material by isotope dilution--mass spectrometry: a candidate definitive method for cortisol.Clinical Chemistry, 1984