Three-Dimensional Intravascular Ultrasound Assessment of Noninjured Edges of β-Irradiated Coronary Segments
- 26 September 2000
- journal article
- other
- Published by Wolters Kluwer Health in Circulation
- Vol. 102 (13) , 1484-1489
- https://doi.org/10.1161/01.cir.102.13.1484
Abstract
Background —The “edge effect,” late lumen loss at the margins of the treated segment, has become an important issue in the field of coronary brachytherapy. The aim of the present study was to assess the edge effect in noninjured margins adjacent to the irradiated segments after catheter-based intracoronary β-irradiation. Methods and Results —Fifty-three vessels were assessed by means of 3-dimensional intravascular ultrasound after the procedure and at 6- to 8-month follow-up. Fourteen vessels (placebo group) did not receive radiation (sham source), whereas 39 vessels were irradiated. In the irradiated group, 48 edges (5 mm in length) were identified as noninjured, whereas 18 noninjured edges were selected in the placebo group. We compared the volumetric intravascular ultrasound measurements of the noninjured edges of the irradiated vessels with the fully irradiated nonstented segments (IRS, n=27) (26-mm segments received the prescribed 100% isodose) and the noninjured edges of the vessels of the placebo patients. The lumen decreased (6 mm 3 ) in the noninjured edges of the irradiated vessels at follow-up ( P =0.001). We observed a similar increase in plaque volume in all segments: noninjured edges of the irradiated group (19.6%), noninjured edges of the placebo group (21.5%), and IRS (21.0%). The total vessel volume increased in the IRS in the 3 groups. No edge segment was subject to repeat revascularization. Conclusions —The edge effect occurs in the noninjured margins of radiation source train in both irradiated and placebo patients. Thus, low-dose radiation may not play an important role in this phenomenon, whereas nonmeasurable device injury may be considered a plausible alternative explanation.Keywords
This publication has 17 references indexed in Scilit:
- Ischemic heart disease after mantlefield irradiation for Hodgkin's disease in long-term follow-upRadiotherapy and Oncology, 1999
- EditorialJournal of the American College of Cardiology, 1998
- Calibration and characterization of beta-particle sources for intravascular brachytherapyMedical Physics, 1998
- Morphometric analysis in three-dimensional intracoronary ultrasound: An in vitro and in vivo study performed with a novel system for the contour detection of lumen and plaqueAmerican Heart Journal, 1996
- Luminal loss and site of restenosis after Palmaz-Schatz coronary stent implantationThe American Journal of Cardiology, 1995
- Radiation injury to the heartInternational Journal of Radiation Oncology*Biology*Physics, 1995
- Factors Affecting Late Mortality From Heart Disease After Treatment of Hodgkin's DiseaseJAMA, 1993
- Effect of external beam irradiation on neointimal hyperplasia after experimental coronary artery injuryJournal of the American College of Cardiology, 1992
- Restenosis and the proportional neointimal response to coronary artery injury: Results in a porcine modelJournal of the American College of Cardiology, 1992
- Duplex Imaging and Incidence of Carotid Radiation Injury After High-Dose Radiotherapy for Tumors of the Head and NeckArchives of Surgery, 1990