Oxygen transfer in animal cell culture medium
- 20 August 1987
- journal article
- research article
- Published by Wiley in Biotechnology & Bioengineering
- Vol. 30 (3) , 368-373
- https://doi.org/10.1002/bit.260300307
Abstract
Both kLa and kL measurements were carried out by an unsteady state technique at impeller speeds ranging from 1.6 to 5.8 s−1 in a mechanically agitated animal cell culture vessel of working volume 1.5 L. Checks were made that the time constant of the oxygen electrode was negligible compared to the time for aeration and that the oxygen electrode reading was not a function of agitator speed in the range employed. The kL values by surface aeration of (1.18–3.54) × 10−5 m/s and kLa values by sparged aeration of (2.8–8.5) × 10−4 s−1 were found. The former are in reasonable agreement with published experimental values and the latter in accord with values estimated from published correlations based on agitator power input and aeration rate. The fluids used were water, basal medium, and basal medium supplemented with 5% (v/v) foetal calf serum; for each of these, kL and kLa values were similar. However, the addition of silicone antifoam (6 PPM) reduced the kLa value by ca. 50%.This publication has 13 references indexed in Scilit:
- MASS TRANSFER TO THE FREE INTERFACE IN STIRRED VESSELSChemical Engineering Communications, 1984
- Surface aeration in a small, agitated, and sparged vesselBiotechnology & Bioengineering, 1980
- Exit Effects in Non-Newtonian Liquids. An Experimental StudyIndustrial & Engineering Chemistry Fundamentals, 1979
- A gradientless contactor for experimental study of interphase mass transfer with/without reactionChemical Engineering Science, 1974
- Gas Absorption Rates at the Free Surface of a Flowing Water Stream. Effects of a Surfactant and of Surface BafflesIndustrial & Engineering Chemistry Process Design and Development, 1973
- The supply of oxygen to submerged cultures of BHK 21 cellsBiotechnology & Bioengineering, 1972
- The cultivation of animal cells at controlled dissolved oxygen partial pressureBiotechnology & Bioengineering, 1968
- Long‐lived steam‐sterilizable membrane probes for dissolved oxygen measurementBiotechnology & Bioengineering, 1967
- Submerged culture of hamster kidney cells in a stainless steel vesselBiotechnology & Bioengineering, 1965
- Steam sterilizable probes for dissolved oxygen measurementBiotechnology & Bioengineering, 1964