Selective spectrophotometric determination of cobalt(II) using 2,2′-dipyridyl-2-pyridylhydrazone and a flow injection manifold
- 1 January 1995
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 120 (5) , 1593-1598
- https://doi.org/10.1039/an9952001593
Abstract
Micro-amounts of cobalt(II) were determined spectrophotometrically at 500 nm using a flow injection manifold and 2,2′-dipyridyl-2-pyridylhydrazone (DPPH) as a colour-forming reagent. The various chemical and physical variables were optimized and a study of interfering ions was also carried out. A linear calibration graph was obtained for 0–12.0 mg l–1 cobalt(II), at a sampling rate of 90 injections per hour. The accuracy and reproducibility were very good (sr= 0.4%), the limit of detection was 0.017 mg l–1 and the limit of quantitation was 0.031 mg l–1. The method was found to be adequately selective owing to the fact that the strongly acidic medium used prevented the formation of complexes of the reagent with other ions. The method has been successfully applied to the determination of cobalt in cyanocobalamin (vitamin B12).Keywords
This publication has 25 references indexed in Scilit:
- Flow-injection preconcentration of Co(II) on 1-nitroso-2-naphthol-3,6-disulphonate-modified alumina for flame atomic absorption spectrometryAnalytica Chimica Acta, 1994
- Flow-injection chemiluminescence determination of cobalt(II) and manganese(II)Analytica Chimica Acta, 1993
- Flow injection on-line separation and preconcentration for electrothermal atomic absorption spectrometry. Part 2. Determination of ultra-trace amounts of cobalt in waterJournal of Analytical Atomic Spectrometry, 1991
- Utilisation of kinetic-based flow injection methods for the determination of chlorine and oxychlorine speciesAnalytica Chimica Acta, 1989
- On-line separation and preconcentration in flow injection analysisAnalytica Chimica Acta, 1988
- Fundamental and practical considerations in the design of on-line column preconcentration for flow-injection atomic spectrometric systemsAnalytica Chimica Acta, 1987
- Determination of ultratrace amounts of cobalt by catalysis of the tiron—hydrogen peroxide reaction with an improved continuous-flow analysis systemTalanta, 1987
- Flow injection analysis for monitoring chemiluminescent reactionsAnalytica Chimica Acta, 1980
- Flow injection techniques. Monitoring chemiluminescent reactions by flow injection analysisProc. Anal. Div. Chem. Soc., 1979
- Flow injection analysesAnalytica Chimica Acta, 1975