Strength of implanted carbon fibers Studies of the lumbar spine in goats
- 1 January 1988
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 59 (1) , 53-55
- https://doi.org/10.3109/17453678809149345
Abstract
The L3-4 supraspinous and interspinous ligaments in 10 goats were replaced with carbon fibers stabilized with silk-suture seizing. The implants were removed after 3 weeks in 5 animals and after 3 months in the other 5. The maximum traction strength of nonimplanted slings was 157±9 kg (M±SD). After implantation, the strength was reduced to 136 ± 17 kg, and after 3 months to 107 ± 9 kg. However, the maximum strength of the spinous processes was 71 ± 19 kg, which was less than the strength of 3-month implants. We concluded that the carbon fiber sling stabilized with silk sutures could be used for replacement of the interspinous ligament.This publication has 5 references indexed in Scilit:
- Carbon fibre used in the late reconstruction of rupture of the extensor mechanism of the kneeInjury, 1987
- The Role of Carbon Fibers in Orthopedic Implants: A ReviewPublished by Springer Nature ,1986
- The role of flexible carbon-fibre implants as tendon and ligament substitutes in clinical practice. A preliminary reportThe Journal of Bone and Joint Surgery. British volume, 1980
- Induction of tendon and ligament formation by carbon implantsThe Journal of Bone and Joint Surgery. British volume, 1977