Characterization of a commercial multileaf collimator used for intensity modulated radiation therapy
- 16 May 2001
- journal article
- Published by Wiley in Medical Physics
- Vol. 28 (5) , 752-756
- https://doi.org/10.1118/1.1367863
Abstract
The characteristics of a commercial multileaf collimator (MLC) to deliver static and dynamic multileaf collimation (SMLC and DMLC, respectively) were investigated to determine their influence on intensity modulated radiation therapy (IMRT) treatment planning and quality assurance. The influence of MLC leaf positioning accuracy on sequentially abutted SMLC fields was measured by creating abutting fields with selected gaps and overlaps. These data were also used to measure static leaf positioning precision. The characteristics of high leaf‐velocity DMLC delivery were measured with constant velocity leaf sequences starting with an open field and closing a single leaf bank. A range of 1–72 monitor units (MU) was used providing a range of leaf velocities. The field abutment measurements yielded dose errors (as a percentage of the open field max dose) of 16.7±0.7% mm−1 and 12.8±0.7% mm−1 for 6 MV and 18 MV photon beams, respectively. The MLC leaf positioning precision was 0.080±0.018 mm (single standard deviation) highlighting the excellent delivery hardware tolerances for the tested beam delivery geometry. The high leaf‐velocity DMLC measurements showed delivery artifacts when the leaf sequence and selected monitor units caused the linear accelerator to move the leaves at their maximum velocity while modulating the accelerator dose rate to deliver the desired leaf and MU sequence (termed leaf‐velocity limited delivery). According to the vendor, a unique feature to their linear accelerator and MLC is that the dose rate is reduced to provide the correct cm MU−1 leaf velocity when the delivery is leaf‐velocity limited. However, it was found that the system delivered roughly 1 MU per pulse when the delivery was leaf‐velocity limited causing dose profiles to exhibit discrete steps rather than a smooth dose gradient. The root mean square difference between the steps and desired linear gradient was less than 3% when more than 4 MU were used. The average dose per MU was greater and less than desired for closing and opening leaf patterns, respectively, when the delivery was leaf‐velocity limited. The results indicated that the dose delivery artifacts should be minor for most clinical cases, but limit the assumption of dose linearity when significantly reducing the delivered dose for dosimeter characterization studies or QA measurements.Keywords
This publication has 11 references indexed in Scilit:
- Abutment region dosimetry for serial tomotherapyInternational Journal of Radiation Oncology*Biology*Physics, 1999
- Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapyMedical Physics, 1998
- Geometric analysis of light‐field position of a multileaf collimator with curved endsMedical Physics, 1997
- Clinical implementation of a commercial multileaf collimator: Dosimetry, networking, simulation, and quality assuranceInternational Journal of Radiation Oncology*Biology*Physics, 1995
- Generation of arbitrary intensity profiles by dynamic jaws or multileaf collimatorsMedical Physics, 1994
- X-ray field compensation with multileaf collimatorsInternational Journal of Radiation Oncology*Biology*Physics, 1994
- An analytical solution for the dynamic control of multileaf collimatorsPhysics in Medicine & Biology, 1994
- Characterization of a multileaf collimator systemInternational Journal of Radiation Oncology*Biology*Physics, 1993
- Clinical dosimetry for implementation of a multileaf collimatorMedical Physics, 1992
- The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimationPhysics in Medicine & Biology, 1992