Use of Bacteriophage MS2 as an Internal Control in Viral Reverse Transcription-PCR Assays
Open Access
- 1 September 2005
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 43 (9) , 4551-4557
- https://doi.org/10.1128/jcm.43.9.4551-4557.2005
Abstract
Diagnostic systems based on reverse transcription (RT)-PCR are widely used for the detection of viral genomes in different human specimens. The application of internal controls (IC) to monitor each step of nucleic acid amplification is necessary to prevent false-negative results due to inhibition or human error. In this study, we designed various real-time RT-PCRs utilizing the coliphage MS2 replicase gene, which differ in detection format, amplicon size, and efficiency of amplification. These noncompetitive IC assays, using TaqMan, hybridization probe, or duplex scorpion probe techniques, were tested on the LightCycler and Rotorgene systems. In our approach, clinical specimens were spiked with the control virus to monitor the efficiency of extraction, reverse transcription, and amplification steps. The MS2 RT-PCR assays were applied for internal control when using a second target hepatitis C virus RNA in duplex PCR in blood donor screening. The 95% detection limit was calculated by probit analysis to 44.9 copies per PCR (range, 38.4 to 73.4). As demonstrated routinely, application of MS2 IC assays exhibits low variability and can be applied in various RT-PCR assays. MS2 phage lysates were obtained under standard laboratory conditions. The quantification of phage and template RNA was performed by plating assays to determine PFU or via real-time RT-PCR. High stability of the MS2 phage preparations stored at −20°C, 4°C, and room temperature was demonstrated.Keywords
This publication has 26 references indexed in Scilit:
- A one step quantitative RT-PCR for detection of SARS coronavirus with an internal control for PCR inhibitorsJournal of Clinical Virology, 2004
- Highly Sensitive Assay for Detection of Enterovirus in Clinical Specimens by Reverse Transcription-PCR with an Armored RNA Internal ControlJournal of Clinical Microbiology, 2004
- Practical Considerations in Design of Internal Amplification Controls for Diagnostic PCR AssaysJournal of Clinical Microbiology, 2004
- Rapid Detection and Differentiation of Human Pathogenic Orthopox Viruses by a Fluorescence Resonance Energy Transfer Real-Time PCR AssayClinical Chemistry, 2004
- Survival of F-Specific RNA Coliphage, Feline Calicivirus, andEscherichia coliin Water: a Comparative StudyApplied and Environmental Microbiology, 2003
- Reduction of Norwalk Virus, Poliovirus 1, and Bacteriophage MS2 by Ozone Disinfection of WaterApplied and Environmental Microbiology, 2003
- Diagnosing Herpesvirus Infections by Real-Time Amplification and Rapid CultureJournal of Clinical Microbiology, 2003
- Rapid-Cycle PCR and Fluorimetry for Detection of MycobacteriaJournal of Clinical Microbiology, 2002
- TaqMan 5′-Nuclease Human Immunodeficiency Virus Type 1 PCR Assay with Phage-Packaged Competitive Internal Control for High-Throughput Blood Donor ScreeningJournal of Clinical Microbiology, 2001
- Use of Bovine Viral Diarrhoea Virus as an Internal Control for Amplification of Hepatitis C VirusVox Sanguinis, 1999