Relative Analgesic Potencies of Ropivacaine and Bupivacaine for Epidural Analgesia in Labor
- 1 April 1999
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 90 (4) , 944-950
- https://doi.org/10.1097/00000542-199904000-00003
Abstract
Background: The minimum local analgesic concentration (MLAC) has been defined as the median effective local analgesic concentration in a 20-ml volume for epidural analgesia in the first stage of labor. The aim of this study was to assess the relative analgesic potencies of epidural bupivacaine and ropivacaine by determining their respective minimum local analgesic concentrations. Methods: Seventy-three parturients at < or = 7 cm cervical dilation who requested epidural analgesia were allocated to one of two groups in this double-blinded, randomized, prospective study. After a lumbar epidural catheter was placed, 20 ml of the test solution was given, either ropivacaine (n = 34) or bupivacaine (n = 39). The concentration of local anesthetic was determined by the response of the previous patient in that group to a higher or lower concentration using up-down sequential allocation. Analgesic efficacy was assessed using 100-mm visual analog pain scores with < or = 10 mm within 30 min defined as effective. An effective result directed a 0.01% wt/vol decrement for the next patient. An ineffective result directed a 0.01% wt/vol increment. Results: The minimum local analgesic concentration of ropivacaine was 0.111% wt/vol (95% confidence interval, 0.100-0.122), and the minimum local analgesic concentration of bupivacaine was 0.067% wt/vol (95% confidence interval, 0.052-0.082). Ropivacaine was significantly less potent than bupivacaine, with a potency ratio of 0.6 (95% confidence interval, 0.49-0.74). No difference in motor effects was observed. Conclusion: Ropivacaine was significantly less potent than bupivacaine for epidural analgesia in the first stage of labor.Keywords
This publication has 21 references indexed in Scilit:
- Dose-dependent Reduction of the Minimum Local Analgesic Concentration of Bupivacaine by Sufentanil for Epidural Analgesia in LaborAnesthesiology, 1998
- Electronic fetal heart rate monitoring: Research guidelines for interpretationAmerican Journal of Obstetrics and Gynecology, 1997
- Extradural pain relief in labour: bupivacaine sparing by extradural fentanyl is dose dependentBritish Journal of Anaesthesia, 1997
- Central nervous and cardiovascular effects of i.v. infusions of ropivacaine, bupivacaine and placebo in volunteersBritish Journal of Anaesthesia, 1997
- Determination of the minimum local analgesic concentration of epidural chloroprocaine hydrochloride in laborInternational Journal of Obstetric Anesthesia, 1997
- The Effect of Epidural Fentanyl on the Minimum Local Analgesic Concentration of Epidural Chloroprocaine in LaborAnesthesia & Analgesia, 1996
- Determination of the Minimum Local Analgesic Concentrations of Epidural Bupivacaine and Lidocaine in LaborAnesthesia & Analgesia, 1995
- Extradural anaesthesia for Caesarean section: a double-blind comparison of 0.5% ropivacaine with 0.5% bupivacaineBritish Journal of Anaesthesia, 1995
- Comparative Systemic Toxicity of Ropivacaine and Bupivacaine in Nonpregnant and Pregnant EwesAnesthesiology, 1995
- COMPARISON OF EXTRADURAL ROPIVACAINE AND BUPIVACAINEBritish Journal of Anaesthesia, 1991