MicroPET: a high resolution PET scanner for imaging small animals
- 1 June 1997
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 44 (3) , 1161-1166
- https://doi.org/10.1109/23.596981
Abstract
MicroPET is a high resolution positron emission tomography (PET) scanner designed for imaging small laboratory animals. It consists of a ring of 30 position-sensitive scintillation detectors, each with an 8/spl times/8 array of small lutetium oxyorthosilicate (LSO) crystals coupled via optical fibers to a multi-channel photomultiplier tube. The detectors have an intrinsic resolution averaging 1.68 mm, an energy resolution between 15 and 25% and 2.4 ns timing resolution at 511 keV. The detector ring diameter of microPET is 17.2 cm with an imaging field of view of 112 mm transaxially by 18 mm axially. The scanner has no septa and operates exclusively in 3D mode. Reconstructed image resolution 1 cm from the center of the scanner is 2.0 mm and virtually isotropic, yielding a volume resolution of 8 mm/sup 3/. For comparison, the volume resolution of state-of-the-art clinical PET systems is in the range of 50-75 mm/sup 3/. Initial images of phantoms have been acquired and are reported. A computer controlled bed is under construction and will incorporate a small wobble motion to improve spatial sampling. This is projected to further enhance spatial resolution. MicroPET is the first PET scanner to incorporate the new scintillator LSO and to our knowledge is the highest resolution multi-ring PET scanner currently in existence.Keywords
This publication has 20 references indexed in Scilit:
- Radiofluorinated L-m-Tyrosines: New In-Vivo Probes for Central Dopamine BiochemistryJournal of Cerebral Blood Flow & Metabolism, 1996
- Optical fiber readout of scintillator arrays using a multi-channel PMT: a high resolution PET detector for animal imagingIEEE Transactions on Nuclear Science, 1996
- Initial results from the Sherbrooke avalanche photodiode positron tomographIEEE Transactions on Nuclear Science, 1996
- A compact position-sensitive detector for PETIEEE Transactions on Nuclear Science, 1995
- Collection of scintillation light from small BGO crystalsIEEE Transactions on Nuclear Science, 1995
- The design and physical characteristics of a small animal positron emission tomographPhysics in Medicine & Biology, 1995
- Study of a high resolution 3D PET scannerNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994
- Performance of multiclad scintillating and clear waveguide fibers read out with visible light photon countersNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994
- Studies of position sensitive photomultipliers in readout of scintillating and waveshifting fibersNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1992
- Test of a new 64-channel PMT for imagingNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1988