Measuring anterior chamber depth with the Orbscan Topography System
- 1 November 1997
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 23 (9) , 1351-1355
- https://doi.org/10.1016/s0886-3350(97)80114-9
Abstract
Purpose: To assess the reliability of the Orbscan Topography System in measuring anterior chamber depth (ACD). Setting: Department of Ophthalmology, Ruprecht-Karls-University of Heidelberg, Heidelberg, Germany. Methods: The Orbscan Topography System is a 3-D, scanning slit beam system for analyzing corneal surfaces as well as structures of the anterior segment, e.g., iris, lens. Reflected surface data points are measured in the x, y, and z axes, creating color-coded true surface topography maps. We measured ACID prior to cataract surgery in 56 eyes of 37 patients (mean age 70.4 years + 13.2 [SD]) using the Orbscan system and, as a control, the Grieshaber Biometric System (ultrasound) and the Jager ACD slitlamp measurement system. Results: Mean ACD values measured with the Orbscan system were 3.23 0.55 mm; ultrasound measurements were 3.27 ± 0.54 mm and Jäger measurements, 3.10 ± 0.55 mm. The average difference between Orbscan and ultrasound values was 0.04 ± 0.15 mm. The correlation coefficient between Orbscan and ultrasound was 0.96 (P < .00001) and between Orbscan and Jäger, 0.899 (P < .0001). Conclusion: The ACID measurements by the Orbscan system were equivalent to common reference measurements.Keywords
This publication has 11 references indexed in Scilit:
- Increase in Iris-Lens Contact After Laser Iridotomy for Pupillary Block Angle ClosureAmerican Journal of Ophthalmology, 1996
- Achieving Emmetropia in Extremely Short Eyes with Two Piggyback Posterior Chamber Intraocular LensesOphthalmology, 1996
- Screening techniques for angle‐closure glaucoma in rural TaiwanActa Ophthalmologica Scandinavica, 1996
- Growth of the Internal and External Eye in Term and Preterm InfantsOphthalmology, 1995
- Intraocular lens power calculation with an improved anterior chamber depth prediction algorithmJournal of Cataract & Refractive Surgery, 1995
- Ocular Dimensions and Refraction in Tibetan ChildrenOptometry and Vision Science, 1995
- Effect of Pilocarpine on Anterior Chamber AnglesJournal of Ocular Pharmacology and Therapeutics, 1995
- Micrometer-Scale Resolution Imaging of the Anterior Eye In Vivo With Optical Coherence TomographyArchives of Ophthalmology (1950), 1994
- Anterior chamber depth after posterior chamber intraocular lens implantationActa Ophthalmologica, 1994
- Biometric Constancy of the Anterior Eye Segment as Demonstrated by Slit Image Photography According to the Scheimpf lug PrincipleOphthalmic Research, 1992