Real‐time amplification of HLA‐DQA1 for counting residual white blood cells in filtered platelet concentrates
- 17 August 2004
- journal article
- research article
- Published by Wiley in Transfusion
- Vol. 44 (9) , 1314-1318
- https://doi.org/10.1111/j.0041-1132.2004.04114.x
Abstract
BACKGROUNDA real‐time polymerase chain reaction (PCR) assay based on amplification of a conserved region of the HLA‐DQA1 locus was developed and validated to assess its suitability in quantitating low levels of white blood cells (WBCs) in filtered platelet (PLT) concentrates (PCs).STUDY DESIGN AND METHODS: To determine the detection limit, serial dilutions of nonfiltered PCs with known quantities of WBCs were prepared. The analytical sensitivity and accuracy of the assay was tested with WBC concentrations ranging from 300 to 0.03 per µL with real‐time PCR and flow cytometry. In addition, 126 random PCs were investigated to assess the capacity of the PCR method to quantify residual WBCs in clinical specimens.RESULTS: A sensitivity of 0.2 WBC equivalent per µL (1.5 × 104WBC equivalents/unit) was achieved. The assay was shown to be accurate and the HLA‐DQA1 gene was reproducibly and consistently amplified in all tested samples (coefficient of variance of < 5%). Overall, the results of the PCR assay correlated well with those of the flow cytometry. The PCR assay detected a concentration of 3 WBCs per µL (approximately 1 × 106WBCs/unit) with 100 percent accuracy.CONCLUSION: Real‐time PCR is rapid, sensitive, accurate, and reproducible. Hence this approach may prove suitable in routine monitoring of residual WBCs in PCs.Keywords
This publication has 10 references indexed in Scilit:
- Crossover study of three methods for low‐level white blood cell counting on two types of flow cytometerCytometry Part B: Clinical Cytometry, 2003
- A rapid and reliable flow cytometric routine method for counting leucocytes in leucocyte‐depleted platelet concentratesVox Sanguinis, 2002
- Quantitation of residual WBCs in filtered blood components by high‐throughput, real‐time kinetic PCRTransfusion, 2002
- A strategy for high throughput HLA-DQ typingJournal of Immunological Methods, 2001
- Leukocyte Counting During Process Control of Leukoreduced Blood ComponentsVox Sanguinis, 2000
- A multicenter study evaluating three methods for counting residual WBCs in WBC‐reduced blood components: Nageotte hemocytometry, flow cytometry, and microfluorometryTransfusion, 2000
- Leukocyte reduction of blood components: Public policy and new technologyTransfusion Medicine Reviews, 2000
- Manual and automated methods for the determination of leukocyte counts at extreme low levels: Comparative evaluation of the Nageotte chamber and the abbott cell dyn 3500 analyserTransfusion Science, 1997
- Manual and automated methods for the determination of leukocyte counts at extreme low levels: Comparative evaluation of the Nageotte chamber and the abbott cell dyn 3500 analyserTransfusion Science, 1997
- Principles of counting low numbers of leukocytes in leukoreduced blood componentsTransfusion Medicine Reviews, 1997