Online brain attenuation correction in PET: towards a fully automated data handling in a clinical environment
- 1 November 1989
- journal article
- research article
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 15 (11) , 712-718
- https://doi.org/10.1007/bf00631762
Abstract
We have improved the calculation of the brain attenuation correction in positron emission tomography (PET) and set up a procedure which allows the clinician to get a fully corrected image in a single reconstruction step, without human intervention. By using a general object description scheme based on polygonal contour trees we are able to calculate the attenuation correction for brain tissue, bone and head holder. The head contour is generated from the emission sinogram. On a set of 15 adult patients, the emission values obtained using this calculated attenuation compare favorably with those obtained with an attenuation resulting from a transmission measurement. Residual discrepancies are attributed to incomplete scatter compensation between emission and transmission. The robustness of the algorithm has been tested on more than 100 brain fluorodeoxyglucose (18FDG) studies in adult patients, including pathological cases. Its applicability for18FDG studies in children and for other tracer such as water (H215O) and fluoroethylspiperone (18FESP) is also presented.Keywords
This publication has 18 references indexed in Scilit:
- Investigation of Count Rate and Deadtime Characteristics of a High Resolution PET SystemJournal of Computer Assisted Tomography, 1988
- Quantitation in Positron Emission Computed TomographyJournal of Computer Assisted Tomography, 1986
- AUTOMATED BODY CONTOUR-DETECTION IN SPECT - EFFECTS ON QUANTITATIVE STUDIES1986
- Scatter Distribution in Transmission Measurements with Positron Emission TomographyJournal of Computer Assisted Tomography, 1986
- Correction for Scattered Radiation in a Ring Detector Positron Camera by Integral Transformation of the ProjectionsJournal of Computer Assisted Tomography, 1983
- Determination of Object Contour from Projections for Attenuation Correction in Cranial Positron Emission TomographyJournal of Computer Assisted Tomography, 1982
- A BOUNDARY METHOD FOR ATTENUATION CORRECTION IN POSITRON COMPUTED-TOMOGRAPHY1981
- Quantitation in positron emission computed tomography: 2. Effects of inaccurate attenuation correction.1979
- Quantitation in Positron Emission Computed TomographyJournal of Computer Assisted Tomography, 1979
- Positron ranges obtained from biomedically important positron-emitting radionuclides.1975