A transducer for the measurement of finger joint moments
- 1 December 1998
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Rehabilitation Engineering
- Vol. 6 (4) , 424-429
- https://doi.org/10.1109/86.736157
Abstract
A device capable of simultaneously measuring the isometric moments generated about the metacarpophalangeal (MP), proximal interphalangeal (PTP), and distal interphalangeal (DIP) joints of all four fingers has been developed. The design utilizes a four-bar linkage to transmit moments, but not forces, to the device. This linkage allows the same device to fit a wide range of hand sizes without recalibration. The device was constructed out of aluminum bars which are strapped to each joint segment and to the back of the hand. Strain gauges mounted to the aluminum bars measure the bending moment on the device, which is directly related to the moment applied about the joint center of rotation. Because of the unique design of the device, it is not necessary to have accurate measurements of the joint center of rotation in order to get accurate moment information. A single device is capable of generating independent measurement of MP extension/flexion, PIP extension/flexion, and DIP extension/flexion. Four of these devices can be used to make simultaneous measurements of all the moments generated by all four fingers. The device also acts as a splint, allowing each joint to be positioned and locked at any angle through the range of motion of the joint. The device is accurate to within /spl plusmn/5.6% of each reading for moments from 10 N/spl middot/cm to 100 N/spl middot/cm and within /spl plusmn/2.0 N/spl middot/cm for moments of 10 N/spl middot/cm or less. If the device configuration is constrained, the accuracy can be improved to /spl plusmn/0.8% of full scale (100 N/spl middot/cm) and /spl plusmn/0.21 N/spl middot/cm for moments of 10 N/spl middot/cm or less. The device can measure both flexion and extension moments up to 100 N/spl middot/cm, and can allow the joints to be fixed at any angle from approximately 10 to 800.Keywords
This publication has 13 references indexed in Scilit:
- Using Torque Arms to Reduce CTDsErgonomics in Design: The Quarterly of Human Factors Applications, 1994
- A conductive polymer sensor for measuring external finger forcesJournal of Biomechanics, 1991
- A new method for measurement of finger-phalangeal forceExperimental Mechanics, 1990
- Implantable functional neuromuscular stimulation in the tetraplegic handThe Journal of Hand Surgery, 1989
- Clinical assessment of hand strength using a microcomputerJournal of Hand Surgery (European Volume), 1985
- Isolated Finger Flexion Force—a Methodological StudyThe Hand, 1981
- Measuring hand-grip force, using a new application of strain gaugesMedical & Biological Engineering & Computing, 1981
- A clinical study of forces generated by the intrinsic muscles of the index finger and the extrinsic flexor and extensor muscles of the handThe Journal of Hand Surgery, 1978
- An apparatus to assess function of the handThe Journal of Hand Surgery, 1978
- Electromyographic Kinesiology of the HandJournal of Bone and Joint Surgery, 1964