2D/3D Image fusion for accurate target localization and evaluation of a mask based stereotactic system in fractionated stereotactic radiotherapy of cranial lesions
- 16 November 2006
- journal article
- Published by Wiley in Medical Physics
- Vol. 33 (12) , 4557-4566
- https://doi.org/10.1118/1.2392605
Abstract
The purpose of this study was to evaluate the accuracy of a two-dimensional (2D) to three-dimensional (3D) image-fusion-guided target localization system and a mask based stereotactic system for fractionated stereotactic radiotherapy (FSRT) of cranial lesions. A commercial x-ray image guidance system originally developed for extracranial radiosurgery was used for FSRT of cranial lesions. The localization accuracy was quantitatively evaluated with an anthropomorphic head phantom implanted with eight small radiopaque markers (BBs) in different locations. The accuracy and its clinical reliability were also qualitatively evaluated for a total of 127 fractions in 12 patients with both kV x-ray images and MV portal films. The image-guided system was then used as a standard to evaluate the overall uncertainty and reproducibility of the head mask based stereotactic system in these patients. The phantom study demonstrated that the maximal random error of the image-guided target localization was +/-0.6 mm in each direction in terms of the 95% confidence interval (CI). The systematic error varied with measurement methods. It was approximately 0.4 mm, mainly in the longitudinal direction, for the kV x-ray method. There was a 0.5 mm systematic difference, primarily in the lateral direction, between the kV x-ray and the MV portal methods. The patient study suggested that the accuracy of the image-guided system in patients was comparable to that in the phantom. The overall uncertainty of the mask system was +/-4 mm, and the reproducibility was +/-2.9 mm in terms of 95% CI. The study demonstrated that the image guidance system provides accurate and precise target positioning.Keywords
This publication has 20 references indexed in Scilit:
- Image-Guided Target Localization for Stereotactic Radiosurgery:Accuracy of 6D versus 3D Image FusionPublished by S. Karger AG ,2006
- Fractionated stereotactic radiotherapy of optic pathway gliomas: Tolerance and long-term outcomeInternational Journal of Radiation Oncology*Biology*Physics, 2005
- Repositioning accuracy of fractionated stereotactic irradiation: assessment of isocentre alignment for different dental fixations by using sequential CT scanningRadiotherapy and Oncology, 2005
- CT simulation in stereotactic brain radiotherapy — analysis of isocenter reproducibility with mask fixationRadiotherapy and Oncology, 1997
- An automatic six-degree-of-freedom image registration algorithm for image-guided frameless stereotaxic radiosurgeryMedical Physics, 1997
- Minimally Invasive Head Holder to Improve the Performance of Frameless Stereotactic SurgeryThe Laryngoscope, 1997
- Fractionated brain stereotactic irradiation using a non-invasive frame:Technique and preliminary resultsRadiation Oncology Investigations, 1994
- Three-dimensional motion analysis of an improved head immobilization system for simulation, CT, MRI, and PET imagingRadiotherapy and Oncology, 1991
- Relocatable frame for stereotactic external beam radiotherapyInternational Journal of Radiation Oncology*Biology*Physics, 1991
- A non-invasive method for fractionated stereotactic irradiation of brain tumors with linear acceleratorRadiotherapy and Oncology, 1990