Amorphous Silicon, Flat-Panel, X-Ray Detector Versus Screen-Film Radiography
- 1 January 1998
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 33 (1) , 33-38
- https://doi.org/10.1097/00004424-199801000-00005
Abstract
The purpose of this phantom study was to assess the diagnostic performance of a self-scanning, solid-state amorphous silicon (a-Si) detector in skeletal radiography using different exposure parameters. A flat-panel detector (15 cm x 15 cm), based on a-Si technology with 143 microm x 143 microm pixel size, 1k x 1k matrix, and 12 bit digital output was used. State-of-the-art screen-film radiography (SFR; speed 400, detector dose 2.5 microGy) was compared with a-Si images taken at doses that were equivalent to a speed of 400, 800, 1,250, and 1,600, respectively. A total of 232 segments of long tubular deer-bones (femur, tibia, humerus, radius) had 110 artificial fractures and 112 cortical defects simulating osteolytic lesions. Receiver operating characteristic analysis was performed for 9,280 observations made by four independent observers. Two-tailed Student's paired t test was used for statistical analysis (95% confidence level). Receiver operating characteristic analysis yielded equivalent results of the a-Si and SFR system. Even at the lowest dose there were no statistically significant differences between both imaging modalities with respect to the detectability of fractures and cortical defects. The results of this study indicate that a-Si detector technology holds promise in terms of dose reduction in skeletal radiography without loss of diagnostic accuracy.Keywords
This publication has 12 references indexed in Scilit:
- Flat-panel digital radiology with amorphous selenium and active-matrix readout.RadioGraphics, 1997
- The AAPM/RSNA physics tutorial for residents. Measures of screen-film performance.RadioGraphics, 1996
- A real-time, flat-panel, amorphous silicon, digital x-ray imager.RadioGraphics, 1995
- Digital skeletal radiography.American Journal of Roentgenology, 1992
- Diagnostic efficacy of digitized images vs plain films: a study of the joints of the fingers.American Journal of Roentgenology, 1992
- Computed radiography in musculoskeletal imaging: state of the art.American Journal of Roentgenology, 1992
- Storage phosphor versus screen-film radiography: effect of varying exposure parameters and unsharp mask filtering on the detectability of cortical bone defects.Radiology, 1990
- Comparison of digital and conventional musculoskeletal radiography: an observer performance study.Radiology, 1990
- Nondisplaced fractures: spatial resolution requirements for detection with digital skeletal imaging.Radiology, 1990