Dual-energy X-ray absorptiometry for the measurement of gross body composition in rats
- 1 June 1996
- journal article
- research article
- Published by Cambridge University Press (CUP) in British Journal of Nutrition
- Vol. 75 (6) , 803-809
- https://doi.org/10.1079/bjn19960187
Abstract
Dual-energy X-ray absorptiometry (DXA) is a novel, non-invasive technique for the measurement of gross body composition in small animals. In the present study the absolute accuracy of the Hologic QDR-lOOOW scanner was assessed by comparison with direct analysis in twelve rats with a range of body fat and bone mineral content (BMC) values. Fat masses measured by DXA and petroleumether extraction were significantly different (P<0·0023). The DXA technique consistently overestimated fat mass by approximately one third of the measured fatcontent. BMC derived from the measurement of Ca in asb gave a mean of 8·26 (range 1·57–15·71)g. BMC measured by DXA was not significantly different for the group as a whole. However, there was a trend for DXA to overestimate BMC in animals with low BMC and underestimate in those with higher BMC, compared with direct analysis, such that the 95% limits of agreement for the two techniques were +2·73 to −2·58g. These results suggest that the present small-animal software developed for use with currently available Hologic machines does not give an accurate measure of gross body composition compared with the results from classical direct analysis.Keywords
This publication has 11 references indexed in Scilit:
- Dual-Energy X-Ray Absorptiometry Measurements of Body Composition: Effects of Depth and Tissue Thickness, Including Comparisons with Direct AnalysisClinical Science, 1995
- Accuracy of dual-energy x-ray absorptiometry for body-composition measurements in childrenThe American Journal of Clinical Nutrition, 1994
- Accuracy, precision, and utility of spine and whole-skeleton mineral measurements by dxa in ratsJournal of Bone and Mineral Research, 1994
- Validation and application of dual-energy x-ray absorptiometry to measure bone mass and body composition in small infantsThe American Journal of Clinical Nutrition, 1993
- Precision and accuracy for rat whole body and femur bone mineral determination with dual X-ray absorptiometryBone and Mineral, 1993
- Dual-energy x-ray absorptiometry of the rat: Accuracy, precision, and measurement of bone lossJournal of Bone and Mineral Research, 1993
- Accuracy of measurements of body composition by dual-energy x-ray absorptiometry in vivoThe American Journal of Clinical Nutrition, 1993
- Sequential and precise in vivo measurement of bone mineral density in rats using dual-energy x-ray absorptiometryJournal of Bone and Mineral Research, 1992
- Nondestructive measurement of bone mineral in femurs from ovariectomized ratsCalcified Tissue International, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986