Precise and accurate measurement of proton T1 in human brain in vivo: Validation and preliminary clinical application
- 1 September 1994
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 4 (5) , 681-691
- https://doi.org/10.1002/jmri.1880040511
Abstract
Precise and accurate inversion-recovery (PAIR) magnetic resonance (MR) measurements of T1 were obtained in eight brain regions and cerebrospinal fluid of 26 healthy volunteers. Accuracy of the technique was assessed by measuring T1 in small fluid volumes with the PAIR technique and with two independent spectroscopic techniques. The mean difference between T1 measured with PAIR and with the two spectroscopic techniques was 3.1% ± 1.3. The precision (reproducibility) of measurements with the PAIR technique was excellent. The coefficient of variation (CV) across 16 measurements in a head phantom was 2.0%, compared with a CV of 2.7% across 45 separate measurements in a single subject. The within-subject CV was 1.8% ± 0.6 in white matter and 1.4% ± 1.0 in basal ganglia. The between-subject CV in 26 healthy volunteers was 3.6% ± 0.6 in white matter and 4.1% ± 1.9 in basal ganglia. Comparison between a patient with an active recurrent brain tumor and an agematched patient with an inactive brain tumor showed that T1 was significantly elevated throughout the brain of the active-tumor patient, especially in white matter tracts, even though no tumor or edema was detected in the white matter on standard MR images. Comparisons between five brain tumor patients and four healthy volunteers of similar age showed that T1 was significantly and substantially elevated throughout the white matter tracts and in the caudate nucleus, putamen, and thalamus. These results are consistent with the hypothesis that white matter tracts are selectively vulnerable to edema and that T1 increases in white matter are a sensitive indicator of patient status or tumor aggressiveness.Keywords
This publication has 35 references indexed in Scilit:
- Relaxation time measurements in NMR imaging. Part I: Longitudinal relaxation timeConcepts in Magnetic Resonance, 1993
- Relationship of perfusion to edema in the 9L gliosarcomaJournal of Neuro-Oncology, 1993
- Magnetic Field Dependence of 1/T1of Human Brain TumorsInvestigative Radiology, 1990
- MR Imaging of Brain Maturation in Normal and Developmentally Handicapped ChildrenJournal of Computer Assisted Tomography, 1990
- In vivo determination of T1 and T2 in the brain of patients with severe but stable multiple sclerosisMagnetic Resonance in Medicine, 1988
- The design of a multiple inversion recovery sequence for T1 measurementMagnetic Resonance in Medicine, 1987
- Reproducibility of relaxation and spin-density parameters in phantoms and the human brain measured by MR imaging at 1.5TMagnetic Resonance in Medicine, 1986
- Correlation of human NMR T1values measuredin vivoand brain water contentThe British Journal of Radiology, 1986
- Multiple field strength in vivo T1 and T2 for cerebrospinal fluid protonsMagnetic Resonance in Medicine, 1986
- Improved Precision in Calculated T1 MR Images Using Multiple Spin-Echo AcquisitionJournal of Computer Assisted Tomography, 1986