Novel Cesium‐Selective Electrodes Based on Lipophilic 1,3‐Bisbridged Cofacial‐calix[6]crowns
- 11 March 2004
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 16 (6) , 472-477
- https://doi.org/10.1002/elan.200402847
Abstract
Five bisbridged calix[6]crowns have been investigated as Cs+ionophore in PVC membrane electrodes. As ionophores, three 1,3‐bisbridged calix[6]crown‐4‐ethers(I–III), 1,3‐bisbridged calix[6]crown‐5‐ether(IV), and 1,3‐bisbridged calix[6]crown‐6‐ether(V) have been evaluated. The membranes all give good Nernstian response in the concentration range from 1×10−7to 1×10−1 M of cesium ion. The best detection limits (−loga=7.08–7.36) are obtained for electrode membranes containing 1,3‐bisbridged cofacial‐calix[6]crown‐4‐ethers(I‐III), and the values are the lowest compared with those reported previously. The highest selectivity coefficients [$\rm{ {\rm p}K_{{\rm Cs}^ + ,{\rm j}}^{{\rm pot}} = 5.53({\rm Cs/Na}),}$3.74(Cs/K), 2.63(Cs/Rb)] are obtained for the membrane of 1,3‐bisbridged calix[6]crown‐4‐ether(II), and these values are also the highest compared with previous reports for Cs+‐ISEs. The highest selectivity towards cesium ion is attributed to the geometrically cofacial positions of two crown‐ethers in calix[6]crowns in order to provide the complex of cesium ion and eight oxygens of cofacial crowns.
Keywords
This publication has 21 references indexed in Scilit:
- Highly Cesium Selective Calix[6]arene Receptors: Synthesis, Structure and Cesium Binding Properties of Calix[6]arene BiscrownBulletin of the Korean Chemical Society, 2002
- Cesium selective electrodes based on novel double flexible spacers bridged biscalix[4]arenesAnalytica Chimica Acta, 2001
- Poly(vinyl chloride) membrane cesium ion-selective electrodes based on lipophilic calix[6]arene tetraester derivativesTalanta, 2000
- Poly(vinyl) chloride membrane caesium-selective electrodes based on doubly crowned 1,3-calix[4]arenesAnalytica Chimica Acta, 1998
- Discrimination between Butylammonium Isomers by Calix[5]arene-Based ISEsAnalytical Chemistry, 1998
- Sodium-selective electrodes based on triester monoacid derivatives of p-tert-butylcalix[4]arene. Comparison with tetraester calix[4]arene ionophoresAnalytica Chimica Acta, 1996
- Selectivity of Calix[4]arene-crown-6 for Cesium Ion in Ise: Effect of the ConformationAnalytical Chemistry, 1995
- Practical Applicability of Silicone Rubber Membrane Sodium-Selective Electrode Based on Oligosiloxane-Modified Calix[4]arene Neutral CarrierAnalytical Chemistry, 1995
- Cesium-selective chemically modified field effect transistors with calix[4]arene-crown-6 derivativesAnalytica Chimica Acta, 1995
- Study of the behavior of calix[4]arene-based sodium-selective electrodes by means of ANOVAAnalytical Chemistry, 1993