The inter rater reliability of the original and of the modified Ashworth scale for the assessment of spasticity in patients with spinal cord injury
- 1 September 1996
- journal article
- clinical trial
- Published by Springer Nature in Spinal Cord
- Vol. 34 (9) , 560-564
- https://doi.org/10.1038/sc.1996.100
Abstract
Thirty patients with spinal cord injury (SCI) were randomly selected to participate in this study which evaluated the inter rater reliability of the original and of the modified Ashworth scale for the assessment of spasticity in the lower limbs. A doctor and a physiotherapist rated the muscle tone of hip adductors, hip extensors, hip flexors and ankle plantarflexors according to the original and to the modified Ashworth scale. The results were analyzed using a Cohen's Kappa statistical test and showed varying levels of reliability for different muscle groups and limbs. Kappa values ranged between 0.21 and 0.61 (mean 0.37). The original scale was slightly more reliable than was the modified scale. However, this difference was not significant (P>0.05), and was not consistent between the two limbs and between different muscle groups. It was concluded that the Ashworth scale is of limited use in the assessment of spasticity in the lower limb of patients with SCI. Further work is required to establish a standardised speed of muscle stretching during the test, or to find more appropriate grades and descriptions of spasticity for this patient group. The effects of training of the raters in the use of the scales also warrants further investigation.Keywords
This publication has 15 references indexed in Scilit:
- Towards a Clinical Measurement of Spasticity?Published by Elsevier ,1995
- Inter-rater reliability of the Ashworth scale in multiple sclerosisClinical Rehabilitation, 1994
- Inter-rater reliability of the modified Ashworth Scale for spasticity in hemiplegic patientsInternational Journal of Rehabilitation Research, 1992
- Objective quantification of spastic hypertonia: Correlation with clinical findingsArchives of Physical Medicine and Rehabilitation, 1992
- A comparison of the assessment of spasticity by the Wartenberg pendulum test and the Ashworth grading scale in patients with multiple sclerosisClinical Rehabilitation, 1992
- Pendulum testing of spasticityJournal of Biomedical Engineering, 1984
- Testing and modelling of spasticityJournal of Biomedical Engineering, 1982
- Comments on the Design of an Instrument to Measure Spasticity in the Arm—SAMEngineering in Medicine, 1982
- The value of postural reduction in the initial management of closed injuries of the spine with paraplegia and tetraplegiaSpinal Cord, 1969
- A Coefficient of Agreement for Nominal ScalesEducational and Psychological Measurement, 1960