Improved peak detection and quantification of mass spectrometry data acquired from surface-enhanced laser desorption and ionization by denoising spectra with the undecimated discrete wavelet transform
- 27 October 2005
- journal article
- research article
- Published by Wiley in Proteomics
- Vol. 5 (16) , 4107-4117
- https://doi.org/10.1002/pmic.200401261
Abstract
Mass spectrometry is being used to find disease‐related patterns in mixtures of proteins derived from biological fluids. Questions have been raised about the reproducibility and reliability of peak quantifications using this technology. We collected nipple aspirate fluid from breast cancer patients and healthy women, pooled them into a quality control sample, and produced 24 replicate SELDI spectra. We developed a novel algorithm to process the spectra, denoising with the undecimated discrete wavelet transform (UDWT), and evaluated it for consistency and reproducibility. UDWT efficiently decomposes spectra into noise and signal. The noise is consistent and uncorrelated. Baseline correction produces isolated peak clusters separated by flat regions. Our method reproducibly detects more peaks than the method implemented in Ciphergen software. After normalization and log transformation, the mean coefficient of variation of peak heights is 10.6%. Our method to process spectra provides improvements over existing methods. Denoising using the UDWT appears to be an important step toward obtaining results that are more accurate. It improves the reproducibility of quantifications and supplies tools for investigation of the variations in the technology more carefully. Further study will be required, because we do not have a gold standard providing an objective assessment of which peaks are present in the samples.Keywords
This publication has 24 references indexed in Scilit:
- Reproducibility of SELDI-TOF protein patterns in serum: comparing datasets from different experimentsBioinformatics, 2004
- Urine protein profiling with surface-enhanced laser-desorption/ionization time-of-flight mass spectrometryKidney International, 2004
- Signal denoising and baseline correction by discrete wavelet transform for microchip capillary electrophoresisElectrophoresis, 2003
- A comprehensive approach to the analysis of matrix‐assisted laser desorption/ionization‐time of flight proteomics spectra from serum samplesProteomics, 2003
- Noise reduction for magnetic resonance images via adaptive multiscale products thresholdingIEEE Transactions on Medical Imaging, 2003
- A data-analytic strategy for protein biomarker discovery: profiling of high-dimensional proteomic data for cancer detectionBiostatistics, 2003
- Noise reduction in directional signals using multiple morse wavelets illustrated on quadrature doppler ultrasoundIEEE Transactions on Biomedical Engineering, 2003
- Analysis of raw microneurographic recordings based on wavelet de-noising technique and classification algorithm: wavelet analysis in microneurographyIEEE Transactions on Biomedical Engineering, 2003
- Comprehensive Proteomic Analysis of Breast Cancer Cell Membranes Reveals Unique Proteins with Potential Roles in Clinical CancerJournal of Biological Chemistry, 2003
- New desorption strategies for the mass spectrometric analysis of macromoleculesRapid Communications in Mass Spectrometry, 1993