Accurate vessel width measurement from fundus photographs: a new concept.
Open Access
- 1 January 1994
- journal article
- research article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 78 (1) , 24-29
- https://doi.org/10.1136/bjo.78.1.24
Abstract
Accurate determination of retinal vessel width measurement is important in the study of the haemodynamic changes that accompany various physiological and pathological states. Currently the width at the half height of the transmittance and densitometry profiles are used as a measure of retinal vessel width. A consistent phenomenon of two 'kick points' on the slopes of the transmittance and densitometry profiles near the base, has been observed. In this study, mathematical models have been formulated to describe the characteristic curves of the transmittance and the densitometry profiles. They demonstrate the kick points being coincident with the edges of the blood column. The horizontal distance across the kick points would therefore indicate the actual blood column width. To evaluate this hypothesis, blood was infused through two lengths of plastic tubing of known diameters, and photographed. In comparison with the known diameters, the half height underestimated the blood column width by 7.33% and 6.46%, while the kick point method slightly overestimated it by 1.40% and 0.34%. These techniques were applied to monochromatic fundus photographs. In comparison with the kick point method, the half height underestimated the blood column width in veins by 16.67% and in arteries by 15.86%. The characteristics of the kick points and their practicality have been discussed. The kick point method may provide the most accurate measurement of vessel width possible from these profiles.Keywords
This publication has 14 references indexed in Scilit:
- Retinal vessel measurement: comparison between observer and computer driven methodsAlbrecht von Graefes Archiv für Ophthalmologie, 1992
- Retinal circulation times in diabetes mellitus type 1.British Journal of Ophthalmology, 1991
- Responses of the retinal circulation to systemic autonomic stimulation in diabetes mellitusEye, 1989
- Evaluation of micrometric and microdensitometric methods for measuring the width of retinal vessel images on fundus photographsAlbrecht von Graefes Archiv für Ophthalmologie, 1988
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Altered Retinal Vascular Response to 100% Oxygen Breathing in Diabetes MellitusOphthalmology, 1984
- Bidirectional LDV system for absolute measurement of blood speed in retinal vesselsApplied Optics, 1979
- Monochromatic Ophthalmoscopy and Fundus PhotographyArchives of Ophthalmology (1950), 1977
- SOME ESSENTIAL OPTICAL FEATURES OF THE ZEISS FUNDUS CAMERAActa Ophthalmologica, 1977