Determining carotid artery pressure from scaled diameter waveforms: comparison and validation of calibration techniques in 2026 subjects
- 9 October 2008
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 29 (11) , 1267-1280
- https://doi.org/10.1088/0967-3334/29/11/003
Abstract
Calibrated diameter distension waveforms could provide an alternative for local arterial pressure assessment more widely applicable than applanation tonometry. We compared linearly and exponentially calibrated carotid diameter waveforms to tonometry readings. Local carotid pressures measured by tonometry and diameter waveforms measured by ultrasound were obtained in 2026 subjects participating in the Asklepios study protocol. Diameter waveforms were calibrated using a linear and an exponential calibration scheme and compared to measured tonometry waveforms by examining the mean root-mean-squared error (RMSE), carotid systolic blood pressure (SBPcar) and augmentation index (AIx) of calibrated and measured pressures. Mean RMSE was 5.2(3.3) mmHg (mean(stdev)) for linear and 4.6(3.6) mmHg for exponential calibration. Linear calibration yielded an underestimation of SBPcar by 6.4(4.1) mmHg which was strongly correlated to values of brachial pulse pressure (PPbra) (R = 0.4, P < 0.05). Exponential calibration underestimated true SBPcar by 1.9(3.9) mmHg, independent of PPbra. AIx was overestimated by linear calibration by 1.9(10.1)%, the difference significantly increasing with increasing AIx (R = 0.25, P < 0.001) and by exponential calibration by 5.4(10.6)%, independently of the value of AIx. Properly calibrated diameter waveforms offer a viable alternative for local pressure estimation at the carotid artery. Compared to linear calibration, exponential calibration significantly improves the pressure estimation.Keywords
This publication has 28 references indexed in Scilit:
- How to assess mean blood pressure properly at the brachial artery levelJournal Of Hypertension, 2007
- Atenolol and Eprosartan: Differential Effects on Central Blood Pressure and Aortic Pulse Wave VelocityAmerican Journal of Hypertension, 2006
- Validation of the Omron HEM-907 device for blood pressure measurementBlood Pressure Monitoring, 2002
- Estimation of Central Aortic Pressure Waveform by Mathematical Transformation of Radial Tonometry PressureCirculation, 1997
- Automated detection of local artery wall thickness based on M-line signal processingUltrasound in Medicine & Biology, 1997
- Validation of Carotid Artery Tonometry as a Means of Estimating Augmentation Index of Ascending Aortic PressureHypertension, 1996
- Assessment of the distensibility of superficial arteriesUltrasound in Medicine & Biology, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new modelJournal of Biomechanics, 1984
- Stiffness and elastic behavior of human intracranial and extracranial arteriesJournal of Biomechanics, 1980