Abstract
Our purpose was to perform a comprehensive review of our experience with compression of postcatheterization groin pseudoaneurysms.Two hundred eighty-one patients underwent 306 sonographically guided compression procedures on 297 groin pseudoaneurysms after femoral artery catheterization. The medical records, cardiac catheterization reports, and sonographic images were reviewed to determine patient demographics, type of catheterization procedure performed, sheath size, access site, interval from sheath removal to compression, anticoagulation status, pseudoaneurysm dimensions, complications, and follow-up information. Statistical analysis was performed using Pearson's chi-square and Kendall tau tests.The success rate for the initial compression attempt was 72.1%. Of the 83 failed compression attempts, 12 patients underwent a second attempt, of which seven attempts were successful. Therefore, counting both first and second attempts, the success rate was 74.4%. A strong negative correlation existed between an...