Quantification of arteriolar density and embolization by microspheres in rat myocardium
- 1 April 1988
- journal article
- research article
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 254 (4) , H636-H650
- https://doi.org/10.1152/ajpheart.1988.254.4.h636
Abstract
We developed a technique for in vitro determination of arteriolar densities. Hearts, obtained from anesthetized rats and perfused by the Langendorff method, were fully dilated with adenosine and were arrested with an elevated potassium concentration. After a stabilization period, the hearts were perfused with a buffered fixative for some minutes to obtain a nonvital vasculature. After fixation, perfusion was switched back to control for some minutes. The hearts were then perfused with a medium containing a low concentration of microspheres: either pollen grains [Urtica dioica (15.4 microns), Betula (23.5 microns), or Phleum pratense (36.5 microns)] or polystyrene microspheres (15 microns). The perfusion was switched back to the standard medium after flow had been reduced to between 83 and 57% of control flow. Microscopic observations of microsections revealed that the percentages of arterioles embolized by one microsphere were 64% for the 15.4-microns, 74% for the 15-microns, 78% for the 23.5-microns, and 72% for the 36.5-microns microspheres. The percentages of arterioles embolized with two microspheres were 20, 15, 15, and 16%, respectively. The arteriolar densities were calculated from the total fractional reduction in coronary flow, the amount of microspheres injected, the wet heart weight, and the degree of occupancy, which corrects for the multiple embolization of the arterioles. The arteriolar densities in the rat hearts were 162.4 +/- 54.9 mg-1 (N = 6) for polystyrene microspheres of 15 microns, 161.5 +/- 81.1 mg-1 (N = 15) for 15.4-microns microspheres, 31.6 +/- 7.8 mg-1 (N = 9) for 23.5-microns microspheres, and 13.0 +/- 2.4 mg-1 (N = 8) for 36.5-microns microspheres.This publication has 16 references indexed in Scilit:
- Effect of exogenous angiotensin II on renal hemodynamics in the awake rat. Measurement of afferent arteriolar diameter by the microsphere method.Circulation Research, 1980
- Propagation velocity and reflection of pressure waves in the canine coronary arteryAmerican Journal of Physiology-Heart and Circulatory Physiology, 1979
- Diameter of afferent arterioles during autoregulation estimated from microsphere data in the dog kidney.Circulation Research, 1978
- Sephadex-induced reduction of coronary flow in the isolated rat heart: A model for ischemic heart diseaseJournal of Molecular and Cellular Cardiology, 1977
- Effect of steric restriction on the intracortical distribution of microspheres in the dog kidney.Circulation Research, 1976
- Diameter of the Afferent Arteriole in the Dog Kidney Estimated by the Microsphere MethodScandinavian Journal of Clinical and Laboratory Investigation, 1975
- The Input Impedance of an Assembly of Randomly Branching Elastic TubesBiophysical Journal, 1966
- The pattern of the microcirculatory bed in the ventricular myocardium of domestic mammalsJournal of Anatomy, 1965
- PHASIC VARIATIONS IN PERIPHERAL CORONARY RESISTANCE AND THEIR DETERMINANTSAmerican Journal of Physiology-Legacy Content, 1935
- Untersuchungen am überlebenden SäugethierherzenPflügers Archiv - European Journal of Physiology, 1895